Site Search Results
249 results found with an empty search
- Otellerde Engelli Acil Durum Sesli , Işıklı ve Titreşim ile Uyarı Cihazı | Platin Teknoloji
Yastik altı uyarı cihazı ile duyma güçlüğü çeken bireyler için titreşim ile uyarı ve etkin acil durum uyarısı Under Cushion Emergency Warning Alarm Device Especially deaf and hard of hearing disabled individuals who are in sleep cannot hear the siren sounds in emergency situations such as fire and disasters that require evacuation. Platinum Technology; We offer solutions with cushion vibration devices integrated into the central fire detection system to warn individuals with hearing difficulties in emergency situations. As an example, when we consider a hotel project: Conventional siren lines of a fire detection system in accordance with standards will be 24 Vdc and the line will be energized at the time of alarm .. Special sockets to be placed on the bed heads from the central siren line during the first construction of the building and these sockets are connected to the pillow under the pillow. Vibration devices and sirens will be warned when they are active. It is not affected by power interruptions because it receives voltage from the central system. You can use it in all bedrooms with suitable socket infrastructure. It is compatible with conventional siren lines of all fire detection systems regardless of brand. Provides an effective warning. It is CE approved and tested to all current British and European standards such as EN 61000-6-1: 2001. FOR OUR OTHER ELECTRONIC ACCESSIBILITY SOLUTIONS
- Güneş enerjisi santralleri | Platin Teknoloji
güneş enerjisi santrallerine özel elektronik güvenlik çözümleri sunuyoruz Power Plants Special Solutions Solar, Wind and Hydroelectric power plants have serious initial investment costs. Our priority measures will be to protect the investment and minimize its risks. In addition, considering their contribution to meeting the electricity needs of our country as a business; Prolonged power outages cause serious problems. It can cause big problems that cannot be measured with money. Long-term power outages for electrical power-dependent hospitals and other emergency services can be costly of living. Platinum technology offers security solutions with thermal imaging cameras at critical points of the electricity network as well as in GES and RES power plants. To prevent damage from possible terrorist attacks as well as ordinary crimes such as theft, it is extremely important to ensure continuity of power distribution through the security of solar power plants and switchyards. There are other threats to this risk. Problems caused by equipment that has completed its useful life or malfunction can be very dangerous. Therefore, online thermal monitoring solar panels switchyards can be monitored in the security system. By constantly monitoring several switch parts of the electrical substation, we ensure that faults are detected as they evolve. In this case, the power company can redirect power through other parts of the infrastructure to avoid immediate downtime. This saves repair crews some time to order parts and schedule repairs. The combined alarm system that resolves environmental security and operational risks with a thermal camera provides a high return on investment. "By combining both security and condition monitoring systems in a single system, this system has a high added value. The number of failures of the institution is reduced by an average of 20% and thus, serious savings are achieved. With the thermal camera, it is possible to monitor the temperatures of energy transmission lines and critical parts in the substation. An alarm is activated if any point in the camera's field of view reaches a temperature higher than the preset threshold temperature. FIRE DETECTION AND WARNING SYSTEM: Controlling the fire risk with the fire detection system to be installed in all closed areas within the facility.It provides instant detection of the first formation of the fire in the form of particles and allows the fire to be intervened before it grows. For this purpose, the fire alarm systems installed by Platin Teknoloji prevent the life-threatening of the personnel in the environment and material damage to the building. The system includes a fire control panel. It evaluates the warnings coming from various type detection elements suitable for the needs of your business and activates the sirens, flashers, telephone dialer. It delivers detailed information to the relevant manager and security personnel. While all these events are taking place, it is ensured that the alarm scenarios previously prepared are activated by sending information to other systems from the moment the fire is detected. CLOSED CIRCUIT CAMERA SYSTEMS: GES - HEPP - RES camera systems, which are used to minimize private security and operational risks in accordance with the specific needs of the energy sector, produce indispensable solutions for operational safety. We offer i camera solutions and DVR recording device and command control center solutions suitable for all kinds of business and manufacturing conditions. Our products do not only register. It produces alarm scenario solutions in order to prevent the occurrence of events, problems and risks by performing event analysis. All systems record in the structure and quality determined by the institution and provide access to images of appropriate quality when necessary. ELECTRIC PANELS AUTOMATIC FIRE EXTINGUISHING: In the GES - HES - RES energy sector, cabin-type extinguishing systems that provide low initial investment and operating costs and high performance are used for electrical panels and cabins where risks are concentrated. It provides effective extinguishing with FM 200 and equivalent HFC227ea and HFC125 etc. extinguishing gases used in fire extinguishers. They are odorless, colorless, non-residual gases that do not harm electrical devices. WATER MOISTURE DETECTION AND ALARM SYSTEMS: In the GES - HES - RES energy sector, especially to prevent damage to the facility as a result of leakage and humidity that will occur out of control from electrical fields, to detect possible raids, to warn the relevant parties and to activate the water discharge engine, heating system, ventilation system according to the scenario are solutions. CABLE TRAYS, VENTILATION SYSTEMS FIRE DETECTION AND DETECTION SYSTEMS: With a special sensor cable to be installed in high risk and difficult to detect areas such as electrical installations and ventilation ducts, sudden temperature changes are detected at the points where it is located and fire is detected before it occurs. Linear Heat Detection is a versatile and economical fire detection product. Considering the initial investment, maintenance, operating costs and operating performance, .Extrem offers economical and performance solutions for fire detection needs. Our experts provide solutions to minimize risks specific to the GES - HES - RES energy sector. Please contact us for special solutions for your projects in Turkey and all countries in our service area.
- WC , Bathroom Corded Panic Alarm Systems | Platinum Technology
Islak hacim wc banyo acil ipli panik alarm sistemi Wireless WC, Bathroom String Panic Alarm Systems Public service providers and people live collectively; Hospitals, health centers, etc. Business centers, plaza, shopping malls, shops, etc. shopping areas Station, Station, airport etc. fields various buildings Platinum technology experts provide panic button alarm and notification systems that enable rapid information and effective intervention in emergency and health risks in general areas and especially in special areas such as WC and Bathroom. Wireless solutions for application in existing buildings. Wireless WC line call solutions, especially in projects where it is not possible to install cables in hotels, historical buildings, etc. 256 room capacity 2-year battery life 24/7 uninterrupted operation with backup battery LCD display with audible light and room name Password reset Alarm memory Event memory Health alarm, Panic alarm integration Call center connection for independent buildings FOR OUR OTHER ELECTRONIC ACCESSIBILITY SOLUTIONS
- Akıllı Kamera Sistemleri | Platin Teknoloji
yeni nesil olay analizi yapan akıllı güvenlik kamerası çözümleri Smart Camera Systems Not only seeing, not recording! New generation camera systems that provide active security that analyze, warn and prevent events from the image. People Counting Systems Has there been fewer visitors, or has there been a decrease in the number of customers with no noticeable change in the number of visitors? Here is the answer to this critical question, Face Recognition and Equivalent Detection Software Facial features are defined as very important distinguishing features that individuals have innate, such as fingerprints, that make them different and unique from other people. We offer an effective analysis solution through the camera Image and Event Analysis Software It is not possible to view the cameras with the human eye and to interpret the images. Due to all these needs, image - event analysis software has been developed that interprets the images taken from Platin Technology cameras and enables the scenarios determined beforehand. Plate Recognition and Analysis Software Your system, which enables license plate recognition and recording from the camera image, has been developed to ensure safe vehicle circulation and record license plates. Security Automation and Integration Software CCTV system, Fire detection and notification system, Access Control system and all weak current systems central rooftop software solutions that provide integration Construction and Event Cameras It offers solutions with event cameras that enable the visualization of the movements in the construction, event, concert, fair grounds as short films, the development of the building in the construction operations as a timelapse short film. IP Camera Web Live broadcast If you want to monitor your IP based cameras that you use in your security system from your website. Solution In Platinum technology, we enable you to broadcast your brand and model independent IP cameras without the need for an additional codec, player, password etc. and watch them from any browser and desktop and mobile devices. Thermal Camera And Special Software Solutions We offer effective security solutions with thermal cameras that function in absolute darkness. You can detect motion from the obtained image and analyze environmental risks. Fixed objects such as tree fences etc., environmental effects such as rain and snow in the environment do not create false alarms. Smart, Environmental, Safe Pole It is time to switch from classic poles where lighting is provided in the streets and advertising postings are hung on some central areas, to smart poles. So what is there in the smart pole; Solar Led Fixture for lighting, Wi-fi, Smart Camera, Air quality, Panic button, Intercom advertising area, Solar charging station Perimeter Security Solutions with Radar Thanks to the developing technology and smart cameras in all areas such as military facilities, industrial areas, ports, customs areas etc. where environmental security is at the forefront, it is possible to ensure environmental security by using only IP camera system. If the fog does not settle, if it does not snow, you are safe. The solution will be a new generation integrated radar. Wireless Solar Camera Systems Professional camera system communication solutions that can work with solar energy even if there is no electricity are offered with wireless cameras as a solution in areas that require serious modifications and costs in cable routing. Automatic Voice Light Alert and Speaking You can get support from Platin Technology experts for sound and light warning solutions that can be integrated with the existing IP Camera system and software specific to your Perimeter Security Project. Akıllı Kamera Sistemleri: Hizmetler
- Turnike Geçiş Kontrol Sistemleri | Platin Teknoloji
platin teknoloji turnike geçiş kontrol uygulamaları ile daha güvenlik risklerden uzak ve mimari açıdan şık işletme çözümleri Turnstile Access Control Systems Turnstile control systems are used to control the passages in places with heavy human traffic and at points and places where the passage should be made within a certain order. All turnstile access systems are microprocessor-based and allow only one person to pass at a time. Information can be transferred and received directly to the turnstiles via computer. Card readers, fingerprints, readers etc. mounted on the turnstiles. Thanks to them, they can work integrated with access control systems. Turnstiles have optional manual or automatic drop arm feature and illuminated and audible indicators. Turnstiles are of electromechanical structure and are mostly used to control entrances in places such as subways, stadiums, plazas, factories, etc. Turnstiles are produced to provide motion control in places where entry and exit are made. At the same time, they can be used wherever you want with their aesthetic appearance as they ensure that unwanted people are not allowed to pass because the passages are controlled. Some models of the turnstiles are equipped with pressure sensitive covers or infrared ray barrier detectors, and they send an alarm message to the access control system in cases of unauthorized and inconvenient passes from under or above the turnstile arm or by pressing on the turnstile. Our turnstile types - 3 arm turnstiles - Full height turnstiles - Fast access turnstiles - Motorized Turnstiles - Hygiene Turnstiles - Disabled entrance doors Platin Technology uses high quality domestic products to support domestic producers in its projects. Please contact us to get information about solutions specific to your project and our products.
- Jam CDBi-485 Su baskın Dedektörü | Platin Teknoloji
jam aqua alarm su baskını sızıntıalgılama ve alarm . leak dedection Jam Aqua Alarm CDBi-485 Zone Detector Module Field detector module for connection to the detection cable. It is made of stainless and ABS plastic. LED on the module and internal alarm sound to give local alarm indication. For connection to the I-Zone Mini control panel. FEATURES 'Aqualarm' CDBi-485 Zone Detector Module, one purpose ABS Box, housing of the electronic circuit. A locking line socket at one end of the module It is installed to allow the connection of the detection cable. The other end is equipped with cloths For connection to the PCB. There is a red LED at the top of the module. The The red LED will flash to indicate an alarm condition. Alarm status and monitoring Single RS485 connection to the I-Zone Mini control panel. The module comes complete with a End-to-End Resistor Plug; Detection cable. Normal operating voltage: 12 volt dc Quiescent Current: <10mA. Per detector. Alarm Current: <100mA. Per detector. Detector Oscillator frequency: 6kHz Recommended connecting cable: 4 Core Cable 22AWG Screened Twisted Pair Belden Ref 8723 Line voltage drop: 1.5 mV / m. Approvals: BS EN ISO 9001: 1994 EMC Directive 89/336 / EEC CD-X Detect Cable Cable detection for all models of the control panel. Constructed of hard-worn Helegaine 66 nylon extinguishing arms providing greater protection against dust and conductive contamination. Locking plugs and sockets for a secure connection. Available in modular lengths of 1, 2, 5 and 10 meters. For connection to Detector Modules and Placement equipment. FEATURE 'Aqualarm' water leak Detection Cable, two flat tinned copper The braids are separated and protected with Helegaine self-extinguishing nylon 66 sheath. This type of configuration protects the sensing centers against dust, others Conductive contamination types and mechanical damage. Cable available In modular lengths of 1, 2, 5 and 10 / m. Each cable is pre-terminated with a male And female locking line plug and socket. Installation Method When a liquid leaking from the piping needs to be protected, the Detection Cable It should be fixed with cable ties under the pipeline, then steam Gasket or thermal protection installed or fixed in the floorboard Just below the pipeline, using appropriate clips or ties. Where protection is required from a liquid leaking from equipment, e.g. water-cooled Computers, chiller factory, air conditioning units etc. Detection Cable for It is fixed on the floor around the equipment. Cable Voltage: No greater than 2 volts from DC Cable diameter: 8 mm Maximum Detection Cable length: Reconstruction System: 50 / m (including bridge cable). ZLM-500: 500 / m (including leader / jumper cable) Operating temperature range: +1 degrees C to +85 degrees Construction: Self extinguishing polymer 66 Monofilaments according to ISO 3795 Braid with straight canned copper sensing veins. Color: Gray / blue Approvals: BS EN ISO 9001: 1994, EMC Directive 89/336 / EEC CE
- Mobile Kamera Sİstemleri | Platin Teknoloji
mobile kamera sistemleri ile tüm taşıtlarda etkin güvenlik çözümleri Mobile Camera Systems Mobile camera systems produce indispensable solutions for personal and public safety in all motor land and sea vehicles from trains, automobiles, buses, minibuses, vans, motorcycles. We offer camera and mobile DVR, NVR recorder and in-car monitor solutions for all kinds of needs. Our products do not only register. It works integrated with remote access capabilities and alarm scenarios. Mobile Camera Systems consist of security cameras placed inside and outside the vehicle. The images recorded by cameras and Mobile DVR Recording devices can instantly record accidents and events with location, speed, etc. information. Akıllı Mobil Kamera Sistemlerine Buradan Ulaşın
- Sigara , Tütün Dumanı Dedektörü | Platin Teknoloji
sigara dumanı algılama ve alarm dedektöründe tütün dumanına özel sensör ile etkin ve erken algılama sağlanır Cigarette, Tobacco Smoke Detector We offer effective detection with cigarette smoke detector solutions to integrate with building automation, alarm, etc. systems. We offer solutions and alarm detector solutions that detect the smoke of all products that contain tobacco, which are prohibited and harmful to health and pose a risk to use in businesses. The answer to the frequently asked question, "Does the smoke detector make a cigarette?" Although the smoke detector is sensitive to the smoke that creates the fire due to its sensor structure, it will not be able to detect without the formation of the so-called under-smoke environment for tobacco smoke detection. The solution for fast and early cigarette smoke detection is "Anti Tobacco" tobacco smoke detection and alarm detectors. You can minimize your risks with our cigarette smoke detection solutions that help control workforce losses, health and fire risks caused by non-compliance with tobacco use ban in businesses. "Cigarette smoke detection detectors: They are especially sensitive to tobacco and cigarette smoke. Selectable sensitivity level on some models. They are manufactured to meet the needs of different institutions and organizations. Prevention of smoking in prohibited areas beyond your control and detection of cigarette smoke in all areas from theaters to movie theaters, hotels to fairgrounds, from factories to industrial facilities, from textile workshops to chemical areas. It is used to minimize, deter and detect the risks that may occur as a result of uncontrolled smoking, thanks to the audible stimulation of cigarette smoke after detection. Product General Features Easy installation and maintenance Photoelectric detection technology Test function • High sensitivity to tobacco smoke Warning sounds • Can be linked together Optional remote indicator or relay output Guaranteed and high quality products and stable operation Usage areas • Factories • Flammable Flammable material facilities Hotel, hostel and student dormitories WC and changing cabins Textile industry manufacturing and storage areas Advantages • Early and effective cigarette tobacco smoke detection Integration with existing brand-independent alarm systems • Wired and wireless detector options With the two different solutions offered, it can monitor all risks with a central system. You can deter them with wireless solutions. 1. Central system solutions 2. Wireless (Battery powered) solutions Our products are designed to detect tobacco smoke in accordance with its particle structure. It is only possible to detect the smoke that occurs during the use of cigarettes, etc. with cigarette - tobacco detectors manufactured for these purposes. With all other fire and smoke detectors, very dense smoke is required to detect cigarette smoke. You can reach PLATIN TECHNOLOGY experts for special solutions for your business. ''All Detectors are similar in shape to each other. The detector structure of the Cigarette Detector is distinguished from the others by its sensor structure . The detector is designed to detect tobacco particles. '' You can minimize your risks with our cigarette smoke detection solutions that control the workforce losses, health and fire risks caused by non-compliance with the tobacco use ban in businesses. "Cigarette smoke detection detectors: Especially sensitive to tobacco and cigarette smoke. Selectable sensitivity level on some models. They are manufactured to meet the needs of different institutions and organizations. From theaters to movie theaters, from hotels to fairgrounds, from factories to industrial facilities, from textile workshops to chemical areas, preventing smoking and detecting cigarette smoke in prohibited areas beyond your control by your staff and visitors. It is used to minimize, deter and detect the risks that will occur as a result of uncontrolled smoking, thanks to the audible warning after the detection of cigarette smoke. Cigarette Smoke Detector Features • Easy installation and maintenance • Photoelectric sensing technology • Test function • High Tobacco smoke sensitivity • Warning sounds • Interconnectable • Optional remote indicator or relay output • Guaranteed and high quality products and stable operation Cigarette Smoke Detector Usage Areas • Factories • Flammable Flammable Substance Facilities • Hotels, Pensions and student dormitories • WC and changing cabins • Textile industry manufacturing and storage areas Cigarette & Tobacco Smoke Detector Advantages • Early and effective cigarette tobacco smoke detection • Integration with existing brand-independent alarm systems • Wired and wireless detector options With three different solutions offered, it can monitor all risks with a central system. You can make quick and easy installation with wireless solutions. 1. Conventional cigarette smoke detector with control panel 2. Battery powered cigarette smoke detector 3. Relay type cigarette smoke detector Our products are designed to detect tobacco smoke in accordance with its particle structure . It is only possible to detect the smoke that arises from the use of cigarettes, etc., with cigarette-tobacco detectors manufactured for these purposes. With all other fire and smoke detectors, very dense smoke is required to detect cigarette smoke. You can reach PLATIN TECHNOLOGY experts for special solutions for your business. You can reach all our cigarette smoke detection and alarm solutions here.
- Smoke Sabre Duman dedektörü test spreyi | Platin Teknoloji
smoke sabre duman dedektörü test sprey tüpü ile etkin yangın algılama dedektör testi Solo A10 Smoke Detector Test Aerosol All fire detection systems approved by smoke detector manufacturers Solo A10 is preferred by professionals for fire detector testing, thanks to its structure similar to real fire smoke.
- Jam UDP-24 Su Baskını Algılama Dedektörü | Platin Teknoloji
Jam Aqua Alarm UDP-24 Su baskını , taşkını algılama dedektörü otomasyon sistemi bağlantısı için röle tabanlı Jam Aqua Alarm CDBi-485 Zone Detector Module Field detector module for connection to the detection cable. It is made of stainless and ABS plastic. LED on the module and internal alarm sound to give local alarm indication. For connection to the I-Zone Mini control panel. FEATURES 'Aqualarm' CDBi-485 Zone Detector Module, one purpose ABS Box, housing of the electronic circuit. A locking line socket at one end of the module It is installed to allow the connection of the detection cable. The other end is equipped with cloths For connection to the PCB. There is a red LED at the top of the module. The The red LED will flash to indicate an alarm condition. Alarm status and monitoring Single RS485 connection to the I-Zone Mini control panel. The module comes complete with a End-to-End Resistor Plug; Detection cable. Normal operating voltage: 12 volt dc Quiescent Current: <10mA. Per detector. Alarm Current: <100mA. Per detector. Detector Oscillator frequency: 6kHz Recommended connecting cable: 4 Core Cable 22AWG Screened Twisted Pair Belden Ref 8723 Line voltage drop: 1.5 mV / m. Approvals: BS EN ISO 9001: 1994 EMC Directive 89/336 / EEC CD-X Detect Cable Cable detection for all models of the control panel. Constructed of hard-worn Helegaine 66 nylon extinguishing arms providing greater protection against dust and conductive contamination. Locking plugs and sockets for a secure connection. Available in modular lengths of 1, 2, 5 and 10 meters. For connection to Detector Modules and Placement equipment. FEATURE 'Aqualarm' water leak Detection Cable, two flat tinned copper The braids are separated and protected with Helegaine self-extinguishing nylon 66 sheath. This type of configuration protects the sensing centers against dust, others Conductive contamination types and mechanical damage. Cable available In modular lengths of 1, 2, 5 and 10 / m. Each cable is pre-terminated with a male And female locking line plug and socket. Installation Method When a liquid leaking from the piping needs to be protected, the Detection Cable It should be fixed with cable ties under the pipeline, then steam Gasket or thermal protection installed or fixed in the floorboard Just below the pipeline, using appropriate clips or ties. Where protection is required from a liquid leaking from equipment, e.g. water-cooled Computers, chiller factory, air conditioning units etc. Detection Cable for It is fixed on the floor around the equipment. Cable Voltage: No greater than 2 volts from DC Cable diameter: 8 mm Maximum Detection Cable length: Reconstruction System: 50 / m (including bridge cable). ZLM-500: 500 / m (including leader / jumper cable) Operating temperature range: +1 degrees C to +85 degrees Construction: Self extinguishing polymer 66 Monofilaments according to ISO 3795 Braid with straight canned copper sensing veins. Color: Gray / blue Approvals: BS EN ISO 9001: 1994, EMC Directive 89/336 / EEC CE
- Apollo | Platin Teknoloji
apollo yangın algılama alarm ve ihbar sistemleri Apollo Fire Detection and Alarm Systems Apollo Fire detection systems specialize in the design and manufacture of high quality fire detection solutions for commercial and industrial applications. From our base in Havant, near Portsmouth, on the south coast of England, for over 40 years it has designed and manufactured products that protect human life and protect structures from fire risk. During this time, it has grown to produce a variety of subjects ranging from traditional fire detectors to complex analog addressable detectors and software. Apollo fire detection solutions continuously provide innovative solutions and develop technologies with R&D investments. With the planned expansions, Apollo has reached a leading global position in the market for professional fire detection. With regional offices in the UK, America, China, Dubai, Germany and India, as well as a network of partners and distributors on five continents, it has positioned our place as a world-class fire solutions provider. Platin Teknoloji offers solutions in projects across Turkey. We offer our customers custom fire detection solutions approved to national and local standards, wherever they are in the world. Apollo fire safety products are used in many prestigious projects all over the world and in Turkey: Apollo is part of the Halma group of companies. Halma is a more than 250 FTSE listed PLC with over 40 subsidiaries worldwide; All of them are involved in specialist engineering activities. LA81161M2 Loop Intelligent Addressable Fire Alarm Control Panel - 16 Zone LED Indicator, Programmable 2 Siren Outputs, 3 Relay Outputs, 5 Alarm Inputs, Non-Networkable APOLLO A81162M2 Intelligent Addressable Fire Alarm Control Panel - 16 Zone LED Indicator, Programmable 2 Siren Outputs, 3 Relay Outputs, 5 Alarm Inputs - Up to 64 Panels Network Possibility, Repeater Panel Option APOLLO 55000-620APO Intelligent Addressable Optical Smoke Detector APOLLO 55000-885APO Intelligent Addressable Combined Optical Smoke and Fixed Temperature Detector 55000-420APO Intelligent Addressable Temperature DetectorAPOLLO SA5900-908APO Addressable Manual Call Point, with Isolator - Red APOLLO 55000-001APO Addressable Electronic Siren, With Isolator, IP65 - Red APOLLO 55000-009APO Addressable Electronic Flasher, Isolator, IP65 - Red SA4700-102APO Addressable Output Module, APOLLO with Isolator SA4700-100APO Addressable Advanced Input Module with IsolatorAPOLLO 55000-845APO5 Addressable Zone Supervision Module with IsolatorAPOLLO 55000-852APO Addressable Audible Alarm Control Module with IsolatorAPOLLO
- Carrier fire security | Platin Teknoloji
Carrier fire security ürünleri türkiye de With UTC Carrier Fire & Security solutions, we make the world a safer place to live. It operates with the motto. We create and maintain a more comfortable, accessible, efficient, healthy, safe, secure and sustainable environment. UTC Carrier is the leading provider of heating, ventilation, air conditioning and cooling systems, building controls and automation, and fire and security systems that lead to safer, smarter, sustainable and high-performance buildings. EMEA BVBA, part of UTC Fire & Security Carrier Global Corporation, has an expert team of more than 800 employees in 18 countries in Europe, the Middle East and Africa working to protect your people and infrastructures with Fire and Security solutions. Our mission Being the first choice of our customers. We manufacture and supply most of the security technology and offer integrated solutions for residential, commercial and corporate applications. We manufacture and supply most security technologies, offering integrated solutions for residential, commercial and corporate applications. Platin Teknoloji Our fire detection brands that you can reach from Turkey UTC Aritech UTC Kilsen UTC Ziton UTC GST
- Mağazacılık ve Perakende | Platin Teknoloji
Perakende sektörüne özel elektronik güvenlik , kamera , yangın algılama çözümleri Special Solutions for Merchandising and Retail Sector Customer Satisfaction Measurement You have opened a store in the most prestigious point of the shopping mall, you have made architectural applications that are unimaginable to be used by competitors in the store, you sell the best quality products at the most competitive prices, you have trained your staff very well. So how do these affect the customer? People Counting Systems Has there been fewer visitors, or has there been a decrease in the number of customers with no noticeable change in the number of visitors? Here is the answer to this critical question, Customer Welcome Announcement You can automatically greet your customers and visitors who enter your store with a voice announcement, welcome them and remind them of the in-store rules. . Pay attention to social distance, Request the products from the officer. . Face Recognition and Equivalent Detection Software Facial features are defined as very important distinguishing features that individuals have innate, such as fingerprints, that make them different and unique from other people. We offer an effective analysis solution through the camera Store Density Management To prevent sudden and uncontrolled densities in stores, shopping malls and event areas, by following the capacity and making an audible warning when the intensity level increases. We offer counting and announcement solutions that automatically close the entrance doors when they reach the maximum occupancy level. Image and Event Analysis Software It is not possible to view the cameras with the human eye and to interpret the images. Due to all these needs, image - event analysis software has been developed that interprets the images taken from Platin Technology cameras and enables the scenarios determined beforehand. Our experts offer special solutions to minimize the security and operational security risks specific to the retail sector such as chain stores, street stores, markets, restaurants, cafes, street entertainment areas, exhibition areas, discount tents, shopping centers, game parks. CLOSED CIRCUIT CAMERA SYSTEMS: Camera systems, which are used to minimize security and operational risks in accordance with special needs of the retail sector, produce indispensable solutions for business security. We offer i camera solutions and DVR recording device and command control center solutions suitable for all kinds of business and manufacturing conditions. Our products do not only register. It produces alarm scenario solutions in order to prevent the occurrence of events, problems and risks by performing event analysis. All systems record in the structure and quality determined by the institution and provide access to images of appropriate quality when necessary. HUMAN COUNTING AND REPORTING SOLUTIONS: We provide solutions that enable counting of customers and analysis of their movements within the store by analyzing with special software on the camera, where the necessary information is created for the tracking of store circulation and the planning of store-specific operations. KEY MANAGEMENT SYSTEMS: It is ensured that the keys of the store are stored securely and the keys can be easily accessed when necessary, and key management solutions are prevented and securely protected with key management solutions. FIRE DETECTION AND WARNING SYSTEM: Control against fire risk with the fire detection system to be installed in all areas of the store.It provides instant detection of the first occurrence of the fire in the form of particles and allows the fire to be intervened before it grows. For this purpose, the fire alarm systems installed by Platin Teknoloji primarily prevent the personnel in the environment from being in life-threatening danger and material damage to the building. The system has a fire control panel. It evaluates the warnings coming from various type detection elements suitable for the needs of your business and activates the sirens, flashers, telephone dialer. It delivers detailed information to the relevant manager and security personnel. While all these events are taking place, it is ensured that the alarm scenarios previously prepared are activated by sending information to other systems from the moment the fire is detected. ELECTRIC PANELS AUTOMATIC FIRE EXTINGUISHING: Cabinet type extinguishing systems that provide low initial investment and operating costs and high performance are used for electrical panels and cabinets where risks are concentrated. It provides effective extinguishing with HFC227ea and HFC125 etc. extinguishing gases used in fire extinguishers. They are odorless, colorless, non-residual gases that do not harm electrical equipment. WATER MOISTURE DETECTION AND ALARM SYSTEMS: They are the solutions to prevent damage to the establishment as a result of leakage and humidity that will occur out of control from the risky areas such as warehouses, to detect possible raids, to warn the relevant people and to activate the water discharge engine, heating system, ventilation system in accordance with the scenario prepared. AUTOMATIC FIRE EXTINGUISHING SYSTEMS: Solutions are offered to extinguish electrical fires in a very short time for areas with special risks such as in-store system rooms, Automatic extinguishing systems to prevent damage to the business and manufacturing processes. The relevant extinguishing gas / chemical is selected and designed, taking into account the special situation of the establishment and the area where it will be established. The system user will make independent fire detection and initiate the extinguishing process. CABLE TRAYS, VENTILATION SYSTEMS FIRE DETECTION AND DETECTION SYSTEMS: With a special sensor cable to be installed in high risk and difficult to detect areas such as electrical installations and ventilation ducts, sudden temperature changes are detected at the points where it is located and fire is detected before it occurs. Linear Heat Detection is a versatile and economical fire detection product. Considering the initial investment, maintenance, operating costs and operating performance, .Extrem offers economical and performance solutions for fire detection needs. ACCESS CONTROL SYSTEMS: We offer solutions for controlling and reporting the circulation in the store, especially in the areas offered to the use of personnel. The doors of risky rooms are controlled with the access control system due to the determined business, security and occupational safety needs. Control application covers all specified areas. It is possible to report all movements and to make the necessary controls online. The buildings belonging to the enterprise can be controlled and monitored from the same central software wherever they are in the world. FIRE DETECTION AND ALARM SYSTEM TEST EQUIPMENTS: Testing and regular maintenance of systems installed with fire detection equipment is one of the overlooked needs in our country. Platin Technology has offered suitable test gases, cleaning and control apparatus for all detector types such as smoke, heat, gas and carbon monoxide, which make up the fire detection system, to the use of professional operating and fire system maintenance companies. LIVING SOLUTIONS WITHOUT BARRIERS: These are electronic solutions offered for disabled visitors and employees to meet their daily needs risk-free and comfortably within your business and to minimize possible risks. What are the risks? We offer solutions to the need for help and urgent struggle in wet areas, the need for medical assistance in general areas, and the risks of reaching exits without assistance in emergency evacuation processes. EMERGENCY ANNOUNCEMENT AND SOUNDING SYSTEM: Emergency announcement and voice-over systems installed in the store are the solutions used to quickly evacuate customers and personnel in possible emergencies that will provide the necessary ambience by broadcasting in-store music in daily life. Our experts offer solutions to minimize risks specific to the retail industry. Please contact us for special solutions for your projects in Turkey and all countries in our service area.
- Flood Detector Detection and Alarm Systems | Platinum Technology
Flood Detector Detection and Alarm Systems" Flood and Moisture Detection, Alarm Systems Thanks to this system applied to system rooms, cash registers, storage areas and places affected by water and moisture, the system will transfer information to the users who will activate the water discharge engine, heating system, ventilation system as required by the scenario in case of moisture or water formation. Flood detection and alarm system smartphone apps pop up message according to the demands. can send mail and sms. You can also keep all information in the event memory and report it. With the smart phone application, you can manage the system, report it and receive instant notifications. Flood risk in multi-storey buildings: Flood risks in mechanical areas: Due to the creation of mechanical areas in multi-storey buildings in the middle and upper floors of the building, possible leaks in installations containing water, such as heating, cooling, etc., pose serious risks on the floor and below the floor with water leakage. It offers solutions that you can follow instantly. In-floor water and moisture risks: In multi-storey buildings, we recommend the use of water-moisture detection solutions in suspended ceilings and under raised floors in order to detect risks early in order to prevent the problem from affecting the relevant floor and downstairs neighbors in possible installation-induced flooding within the floor. Sensors used for water and moisture detection in floor areas can be point type or effective detection can be made with textile-based nano technology spread type sensors. Detection System _cc781905-5cde-3194-bb3b-136bad-cf-alarm-3194d_cc781905cf Equipment Used - Water detection sensor - Water detection detector - Under-carpet detector for water and moisture detection detector - Surface mounted detector for flood detection detector - Water detection detector Textile Nano technology detector - Humidity detection sensor - Flood Detection and Alarm Control panel - Siren and Flasher - Phone dialer - Web connection module - Mod Bus connection, Building automation integration - SMS module We offer flood early detection and automatic evacuation solutions in structures in areas with flood risk.
- Bankacılık ve Finans | Platin Teknoloji
bankacılık ve finans sektörüne özel elektronik güvenlik çözümleri Special Solutions for the Banking and Finance Sector Our experts, who offer industry-specific solutions for Banks, Stock Exchanges, Brokerage houses, Factoring companies, Financial leasing companies, Headquarters, Branches, Call centers, Regional Directorates of Insurance companies, Cash transfer areas, Cash registers and VIP areas, have produced the following solutions specifically for the Finance sector. BANKING SECTOR DEBT CREDIT AND ANTI-SCAMS SOLUTIONS; The software developed to prevent the use of fake credits, credit cards and bad credits in the banking sector, which occurs with the use of fake IDs / images in the banking sector, works in integration with the system of the bank at all points where transactions are made. It provides comparison of images and identity photos of persons coming without identity information. Thus, it prevents the same person from taking loans from different bank branches using fake IDs in a short time. It is to compare the facial images of the persons taken during the application with the former applications and the facial information of the persons on the black list. FACE RECOGNITION AND ISSUE DETECTION SOFTWARE; The software developed to support the personnel element, one of the security solutions of the institutions, enables the comparison of the images taken from the existing cameras on the existing black list. It also enables the recording of the identity information of all persons entering the institution. Facial information is described as very important distinguishing features that individuals have innate, such as fingerprints, that make them different and unique from other people. This discrimination disappears only in identical twins. The basis of face recognition software is based on the system automatically capturing and comparing some characteristics and features of that face from the images of existing faces. The most important feature of this technology is that it is a technology that provides the desired security in the area where it is applied without causing anyone to experience stress or discomfort. The human faces in the video images to be taken with the existing systems can be automatically detected and followed with these software. FIRE DETECTION AND WARNING SYSTEM; Controlling all areas where the sector works are carried out against the risk of fire.It ensures that the first occurrence of the fire in the form of particles is instantly detected and it allows the fire to be intervened before it grows. For this purpose, the fire alarm systems installed by Platin Teknoloji prevent the life-threatening of the personnel in the environment and material damage to the building. The system includes a fire control panel. It evaluates the warnings coming from various type detection elements suitable for the needs of your business and activates the sirens, flashers, telephone dialer. It delivers detailed information to the call center and security point. While all these events are taking place, from the moment the fire is detected, it is ensured that the previously prepared alarm scenarios are activated by sending information to the elevator, ventilation system, pressurization fans, smoke evacuation system, turnstiles, etc. CLOSED CIRCUIT CAMERA SYSTEMS; Camera systems, which are used to minimize the private security and operational risks of all banking transactions, cash flow and business information, documents and documents in accordance with the sector-specific needs, provide indispensable solutions for operational security. We offer camera solutions and DVR recording device and command control center solutions suitable for all business and manufacturing conditions. Our products do not only register. It produces alarm scenario solutions in order to prevent the occurrence of events, problems and risks by performing event analysis. All systems record in the structure and quality determined by the BRSA and ensure that images of appropriate quality are accessed when necessary. DETECTION OF FLAMMABLE, EXPLOSIVE AND TOXIC CHEMICALS AND GASES; Necessary perceptions are made to minimize the risks caused by flammable explosive gases and chemicals used in the mechanical areas of heating, cooling, etc. of all buildings, and to prevent damage to the personnel and the enterprise. Platinum technology engineers provide customized solutions for your business to identify these risks caused by gases and chemicals and to evacuate them before the risk grows. FIRE DETECTION WITH EXTREMELY SENSITIVE AIR SAMPLING AND ANALYSIS SYSTEMS; The sensitive laser sensor, which continuously samples air from the vault, security and system room, ensures that the quality of the air passing through the sampling room is monitored and the fire is detected at the moment of its occurrence. LASER TYPE FIRE DETECTION AND SMOKE DETECTION EQUIPMENT; Laser beam detectors are used where high ceiling point type fire detection systems do not work efficiently, operating and installation costs will minimize economic and fire risks. The system ensures that the fire is detected at the time of its first occurrence by mutually controlling the beam of light it generates. ELECTRIC PANELS AUTOMATIC FIRE EXTINGUISHING; Cabin-type extinguishing systems that provide low initial investment and operating costs and high performance are used for electrical panels and cabinets where risks are concentrated. It provides effective extinguishing with HFC227ea and HFC125 etc. extinguishing gases used in fire extinguishers. They are odorless, colorless, non-residual gases that do not harm electrical material. WATER MOISTURE DETECTION AND ALARM SYSTEMS; They are solutions to prevent damage to the business as a result of leakage and humidity that will occur out of control from the risky areas for the vault room, warehouse, boiler room, building, to detect possible floods, to warn the relevant people and to activate the water discharge engine, heating system, ventilation system in accordance with the scenario. AUTOMATIC FIRE EXTINGUISHING SYSTEMS; Special risks such as system room, operational areas, vault room etc. that will cause significant damage in the business and solutions that will extinguish electrical fires in a very short time are offered, Automatic extinguishing systems that will prevent damage to the business and manufacturing processes. The relevant extinguishing gas / chemical is selected and designed, taking into account the special situation of the establishment and the area where it will be established. The system user will make independent fire detection and initiate the extinguishing process. CABLE TRAYS, VENTILATION SYSTEMS FIRE DETECTION AND DETECTION SYSTEMS; With a special sensor cable to be installed in areas with high risk and difficult to detect, such as electrical installations and ventilation ducts, sudden temperature changes are detected at the points where it is located, and fire is detected before it occurs. Linear Heat Detection is a versatile and economical fire detection product. Considering the initial investment, maintenance, operating costs and operating performance, .Extrem offers economical and performance solutions for fire detection needs. ACCESS CONTROL SYSTEMS; We offer solutions for controlling and reporting the circulation of personnel and visitors in all areas of the bank. Due to the determined business, security and occupational safety needs, the doors of risky rooms are controlled by an access control system. We offer solutions such as personnel card, fingerprint, eye recognition, etc. at the entrances to these rooms. Access control application covers all determined areas starting from the first entry point of the enterprise. It is possible to report all movements and to make the necessary controls online. The buildings belonging to the enterprise can be controlled and monitored from the same central software wherever they are in the world. TURNSTILE AND BARRIER SOLUTIONS; Building and floor entrances are arranged and limited with turnstiles used in integration with the access control system in all areas where the human traffic in the General Directorates must be controlled. Thus, it is used for the purpose of controlling the transitions at the points and places where the transition should be made within the order determined by the general directorate. All of our turnstiles are microprocessor-based and allow only one person to pass at a time. Turnstiles have automatic falling arm feature and luminous, audible indicators. SYSTEM ROOM ENVIRONMENTAL TRACKING AND REPORTING SOLUTIONS; It has been developed so that important technical rooms can operate without risk. It monitors the criteria such as heat, humidity, fire, smoke, network-ups voltages, unauthorized entry etc. of special rooms such as system rooms and ensures that the relevant persons are warned and reported without a possible detection. In addition to the ability to monitor system parameters, it provides integration with other systems in case of an event. In cases of sudden temperature increases and decreases, ups and network voltages, water and humidity raids, unauthorized entry, etc., the system room provides a warning in the form of e-mail or SMS. In this way, the alarm & technical malfunction that caused the error is detected as soon as possible and effective and fast measures are taken. FIRE DETECTION AND ALARM SYSTEM TEST EQUIPMENTS; Testing and regular maintenance of fire detection system equipment established by making serious investments in enterprises are among the needs that are ignored in our country. Platin Technology has offered suitable test gases, cleaning and control apparatus for all detector types such as smoke, heat, gas and carbon monoxide, which make up the fire detection system, to the use of professional operating and fire system maintenance companies. EMERGENCY ROUTING LUMINAIRES; Especially in multi-storey buildings, in case of a power outage, such as fire, earthquake, the electrical energy of the building or building for safety reasons, when normal lighting is cut due to the opening of a circuit breaker or fuse, devices that automatically activate and direct users to perform evacuation, and systems. EMERGENCY ANNOUNCEMENT AND SOUNDING SYSTEM; Emergency announcement and public address systems are the solutions used for the rapid evacuation and guidance of the employees in the buildings and safely in case of emergency. SECURITY AUTOMATION SOLUTIONS; It installs security automation systems against theft and sabotage. These systems, which are needed today, are the definitive solution to robberies and unauthorized access. The possibility of false alarms of these systems is very low and they provide the opportunity to intervene in the system only with the correct password. There are products and systems with different detection features in security systems according to the purpose and protection system. Electronic systems are integrated with alarms, where the scenarios are activated instantly and necessary precautionary warnings are activated, and the security risks of large-scale areas such as Head Office, Regional Office, branch, Campus, etc. are minimized. KEY MANAGEMENT SYSTEMS; Key management solutions that enable the keys of all areas belonging to the Bank to be easily accessed when necessary and the reporting of key usages ensure that key confusion is prevented and securely protected. DISABLED LIFE SOLUTIONS; These are electronic solutions offered for disabled visitors and employees to meet their daily needs risk-free and comfortably within your business and to minimize possible risks. What are the risks? We offer solutions to the need for help and urgent struggle in wet areas, the need for medical assistance in general areas, and the risks of reaching exits without assistance in emergency evacuation processes. It offers electronic security solutions that will minimize the risks of all business areas in the banking sector. Please contact us for special solutions for your projects in Turkey and all countries in our service area.
- Flood and Moisture Detection, Alarm Systems | Platinum Technology
We offer effective solutions with flood and humidity detection and alarm system. Flood and Moisture Detection, Alarm Systems Thanks to this system applied to system rooms, cash registers, storage areas and places affected by water and moisture, the system will transfer information to the users who will activate the water discharge engine, heating system, ventilation system as required by the scenario in case of moisture or water formation. Flood detection and alarm system smartphone apps pop up message according to the demands. can send mail and sms. You can also keep all information in the event memory and report it. With the smart phone application, you can manage the system, report it and receive instant notifications. Flood risk in multi-storey buildings: Flood risks in mechanical areas: Due to the creation of mechanical areas in multi-storey buildings in the middle and upper floors of the building, possible leaks in installations containing water, such as heating, cooling, etc., pose serious risks on the floor and below the floor with water leakage. It offers solutions that you can follow instantly. In-floor water and moisture risks: In multi-storey buildings, we recommend the use of water-moisture detection solutions in suspended ceilings and under raised floors in order to detect risks early in order to prevent the problem from affecting the relevant floor and downstairs neighbors in possible installation-induced flooding within the floor. Sensors used for water and moisture detection in floor areas can be point type or effective detection can be made with textile-based nano technology spread type sensors.
- vesda xtralis Hava örnekleme dedektörü Türkiye'de | platinteknoloji
Dünyanın ilk ve etkin hava örneklemeli tip erken yangın algılama sisteminin mucidi Vesda Xtralis Ürünleri Türkiye'de . Platin Teknoloji uzmanlığı ve ayrıcalığı ile VESDA OSID New generation Beam Detector Revolutionizing very early warning smoke detection with VESDA, the company has reinvented smoke detection for outdoor areas with Outdoor Smoke Imaging Detection (OSID). OSID by Xtralis provides reliable, cost-effective smoke detection for open areas where fire detection presents unique challenges and very early warning is not always a priority. Solutions for all areas with complex high ceilings with the new generation Beam detector Using imaging technology based on the CMOS Imager, the OSID series offers fast setup and superior detection performance that cannot be achieved using a single photo receiver. A CMOS imager is equivalent to hundreds of thousands of photocells. Automatic setup reduces setup time from hours to minutes. CMOS imagers locate detection targets (Transmitter or Reflector) and lock onto it, eliminating building motion issues. The CMOS imager also allows to minimize drastically false alarms caused by foreign body ingress and sunlight saturation. In its simplest configuration, OSID-R (Reflector) uses a viewer and a reflector. It works according to the principle of dimming the light using infrared rays and performs intelligent analysis at the pixel level of its reflector, which offers superior performance. Power and connection occur only in the imager, and the OSID-R only requires a single standard reflector on the opposite wall (not a larger reflector the farther you go). Alongside this stepping model is OSID-DE (Double-ended), which uses a similar CMOS sensor with wired or battery-operated transmitter(s) roughly aligned on the opposite wall within the protected area. The transmitter sends both infrared and ultraviolet coded light signals to the imager. The innovative use of dual light frequencies in an open path device allows OSID-DE to distinguish between real smoke and other solid objects. It offers high resistance to sudden and temporary clouds of dust and vapor, significantly reducing false alarms. The OSID range of outdoor smoke detectors offers a great package for reliable smoke detection in large or open areas. Using CMOS imaging technology, OSID not only provides reliable smoke detection, but is designed for fast setup and reliable operation throughout the detector's lifetime. Installers no longer face lengthy and costly setup processes and callbacks; and end users are no longer bothered by annoying or false alarms about building movement; dust or beam interruption. OSID offers a reliable alternative to heat or flame detectors, which typically start much later in the fire development cycle. Osid Beam Detector Product Options Headunits Xtralis OSI-10 Imager 7° Horizontal, 4° Vertical Shield, min. 30m, max 150m range, use only with standard power emitter, 8mA@1xemitter, 10mA@7xemitter Xtralis OSI-90 Imager 80° Horizontal, 48° Vertical Protection, min. 6m, max 34m range (with standard powerful emitter), min. 12m, max 68m range (with high power emitter) Reflectives Xtralis OSE-SP-01 Standard Power Emitter with Internal Battery Xtralis OSE-SPW Standard Power Emitter, 24V DC External Powered Xtralis OSE-HPW High Power Emitter, External Power Input, 800mA@24V DC Xtralis OSE-HP-01 High Power Emitter with Internal Battery
- Disabled What is sound and light guidance? | Platinum Technology
What is emergency exit guidance with sound and light for the visually and hearing impaired? Project and application details What is Disabled Sound and Light Emergency Exit Guidance? In service buildings open to public use and in all social and cultural areas, when an emergency occurs such as fire, flood, earthquake, etc. , alarm sirens, flashers, horns and warning loudspeakers placed in various parts of the building work simultaneously in as wide an area as possible to warn people against a sudden danger. . There are exit signs and exit signs used to direct the users inside the building to the emergency exit. However, in a smoke-filled environment, emergency signs created by visual guidance may be less pronounced or completely ineffective. Building occupants may not be familiar with the building and associated emergency exit routes, but they can still access emergency exits somehow with directions and signs. So how will people in panic and shock, hearing and visually impaired individuals reach the emergency exit doors without help !! For visually impaired people to evacuate the building quickly without additional support during the evacuation processes of buildings, conventional emergency direction luminaires and signs will not be sufficient and they will experience serious difficulties. Are there any signs? Solutions that will answer the question should be applied. Disabled audible light guiding luminaires are new generation emergency exit evacuation routing solutions. In short, you can define it as a sound exit armature. The human ear can hear sound signals in the range between 20 Hz and 20000 Hz. The human brain provides time differences between the ears with the difference in sound intensity between the ears. Due to the development of directional sound technology, many studies and researches are carried out to compare the escape times of users from the building with the help of directional sound makers with the escape times made with classical visual signals and signs. These studies have generated a large body of data, with research showing that the use of guided sounders has consistently shown a significant reduction in escape times. Experiments were carried out to confirm this information. Wideband tested at different frequency bandwidths. In addition, pure tone signals were also tested as a reference. The tested sound level is fixed at 75 dB. NFPA's Fire Code [11] Annex-A has shown what ambient sound levels can be for different applications. Fire alarm siren sounds should be higher than ambient sound level. The sound of the fire alarm siren, the voice alarm speaker must be at least 15 dB higher than the ambient sound level . In addition, the sound of the directional disabled emergency audible and light directional luminaire should be at least 15 dB lower than the fire alarm, taking into account the comparability between the two sounds. For this reason, two ambient sound levels were taken into account in the tests; For the accuracy of the aforementioned statements, experts have conducted experiments. One below 60 dB, the other 75 dB. In the test, 36 loudspeakers were placed in a 3 meter diameter circle around the subjects. The circle is marked from 0° to 360° and each sound box is placed at the specified degree. Before starting the test, the subject needs to know: 1) Does not move his head during the test, 2) Different sounds will be played and the subject will be asked to indicate where the sound comes from, 3) Each sound will be played 10 times from a randomly changing sound box each time. 5 seconds between each sound. space will be given and the subject will talk about the place of the voice for 5 seconds. must make a decision in 4) In noise impact tests, a noise sound will be played continuously, during which the subject will distinguish and say the location of the guiding sound signal. For each sound, there are 100 test results. In each test, the direction pointed by the subject has a deviation from the audible sound box, and if the deviation is greater than ±5°, the percentage correct numbers will decrease by one. The results are listed in the analysis. Background noise has some influence on identifying the sound source. Where the background noise level is close to that of the test sound, pure tone (mono-frequency) forms are more difficult to locate, whereas broadband sounds with a larger frequency range are more easily located. When the ambient sound level is below 60 dB, three sounds with bandwidths 0.02-20 kHz, 0.3-16 Khz and 0.5-10 kHz met the above condition. But when the mid sound level was 75 dB, only two sound conditions with bandwidths 0.02-20 kHz, 0.3-16 Khz were provided. Besides, it is easier to pinpoint the exact location of wideband audio; however, the frequency bandwidth should be as wide as possible. The Test concluded accordingly, with test subjects correctly locating the sounder at least 75% of the time, according to the British standard BS PAS 41:2003. The engineering application of directional audio technology faces some problems. Commonly used emergency fire alarm sounds cause confusion for building occupants. Users in buildings may not know what to do when they hear the sound. For this reason, there is a need to clarify escapes in addition to the voice alarm and siren. Users who try to go out into the corridor and steer towards the escape stairs after the siren sound at which the emergency warning is made, will proceed confidently to hear the announcements that they will understand that they can reach the fire stairs for emergency escape when they approach the audible and illuminated emergency exit direction luminaire, when they move in the direction of the sound, and that they are approaching with an increasingly clear sound announcement. This message will enable them to move quickly and safely without the need for visual guidance and evacuation sign systems without having knowledge of the Building. Conventional fire alarm and voice alarm systems both emit an audio signal when an emergency occurs in the building. Disabled emergency exit guidance system with audible light is an additional evacuation aid; however, it is not a system that replaces the above-mentioned fire alarm and voice alarm system. Disabled emergency exit sound and light announcement fixtures should be placed above emergency exit doors and in complex corridor turns. However, emergency audio and light guidance products only on fire escape stairs and emergency exit doors may not provide enough directional sound to reach most of the users. In addition, there may be more than one exit in large, open and large buildings, but the sounds of more than one disabled audible lighted emergency exit routing product may interfere with each other and create confusion. For this reason, detailed project work should be done for disabled emergency sound and light guidance device equipment placement and integrated with the fire scenario. Considering this information It is possible to reach the fire doors and escapes with audible and illuminated announcements from the emergency exit doors. In an emergency, the environment can be noisy due to siren sounds. The emergency voice guidance warning sound should be at least 15 dB lower than the ambient sound level. Despite the ambient noise, it can be heard easily. Orientation can be determined It will make it easier to reach the exit points with the increasing sound level as you get closer. FOR OUR DISABLED VOICE LIGHT GUIDANCE PRODUCTS RESOURCES 1 : PAS 41:2003, Directional Sounders-Requirements and tests. BSI, 17 February 2003. 2: Sime, Jonathan. Movement Toward the Familiar Person and Place Affiliation in a Fire Entrapment Setting. Environment and Behavior 17:6(1985) 697-724. 3 : MeClintock, T., et al. A Behavioural Solution to the Learned Irrelevance of Emergency Exit Signage. 2d International Symposium on Human Behavior in Fire, March 26-28, 2001, Boston, MIT InterScience Communications, 23-33. 4 : SFPE Engineering Guide, Human Behavior in Fire, Society of Fire Protection Engineers, Bethesda, Maryland, 2003. 5: DJ Withington, M. Lunch. Directional Sound Evacuation- An Improved System for Way Guidance From Open Spaces and Exit Routes on ships. RINA Passenger Ship Safety Conference, London, UK 2003. 6 : DJ Withington. Faster evacuation from ferries with sound beacons [J]. Fire, 2000: p. 30. 7 : Withington D J. Lifesaving applications of directional sound [J]. Pedestrian and Evacuation Dynamics (Berlin/New York: Springer), 2002. 8 : Withington D J. Localisable alarms [J]. Human factors in auditory warnings, 1999: 33-40. 9 : Van Wijngaarden SJ, Bronkhorst AW, Boer L C. Auditory evacuation beacons [J]. Journal of the Audio Engineering Society, 2005, 53(1/2): 44-53. 10 : Boer LC, van Wijngaarden S J. Directional sound evacuation from smokefilled tunnels[J]. Safe & Reliable Tunnels. Innovative European Achievements, Prague, Czech Republic, 2004. 11 : NFPA72-2013, National Fire Alarm and Signaling Code. NATIONAL FIRE PROTECTION ASSOCIATION OF America. August 29, 2012. 12 : BS8456-2005, Code of practice for design and installation of directional sounder evacuation systems. BSI, 18 Aug 2005. 13 : DANIEL J. O'CONNOR, PE, FSFPE. The psychoacoustic basis and implementation of directional sounders. 2006, National Fire Protection Association. 14 : Directional Sounder with Voice Messaging, Application Guide by System Sensor, 2007 15 : Wenhui Dong, Chunyu Yu, Mei Zhibin Shenyang Fire Research Institute, China 2018 16 : Fire Safety Magazine November -December 2020
- Aerosol type Automatic Fire Suppression Systems | Platinum Technology
Aerosol type automatic fire extinguishing systems extinguish the fire without consuming oxygen, by preventing chemical reactions in the flame at the molecular level. Aerosol Type Automatic Fire Extinguishing Systems With the actions of the world's governments to regulate possible damages to the ozone layer that will reduce global warming, corporate initiatives are accelerating a transition that will leave environmentally harmful HFC fire extinguisher clean materials such as FM-200® (HFC-227ea) to more sustainable alternatives. Novec 1230 has very low GWP, is not ozone depleting, does not circulate in the atmosphere, so it is not subject to regulatory restrictions or reductions. With FM 200, HFC227, etc.Novec 1230, which is used as an alternative to automatic fire extinguishing systems using gas, can be used safely and with less damage to the environment in automatic fire detection solutions of all risky areas. System Design and Operation: For the volume to be protected with NOVEC 1230 gas, the required gas amount is calculated according to NFPA 12 and ISO 14520 standards and rules, NOVEC 1230 tube is selected according to the gas amount, NOVEC 1230 discharge nozzles are placed at the required points in the room installed with a cross zone fire detection system, With the activation of the smoke detectors, current is sent from the panel to the solenoid valve of the NOVEC 1230 system, The entire NOVEC 1230 is discharged in gaseous state to the protected volume within a maximum of 10 seconds. System operation can be done automatically or manually. Examples of Wide Usage Areas IT / Server Rooms Electrical Rooms Data Centers Safes · Museums Art Galleries Archive Facilities
- ACA ES 12L Ekonomik Sesli ve ışıklı acil çıkışa yönlendirme | PLATİN TEKNOLOJİ
ACA ES 12L Ekonomik Sesli ve Işıklı acil çıkışa yönlendirme armatürü ile etkin erişilebilirlik uygulamaları ve acil durum tahliye çözümleri . ACA ES 12 DISABLED SOUND LIGHT GUIDANCE ACA ES12 Voice and Light Announcement Emergency Exit Guidance System for Visually and Hearing Impaired People In public buildings, social and cultural areas, Port, Station, Station, Shopping areas, Stores, Bank, Post center, Market, etc.In case of fire or emergency people are directed to the exits with Emergency Exit signposts placed for evacuation of the building. In accordance with the regulation of accessibility from these buildings, it is necessary to ensure that the buildings are directed to the Emergency exit doors and evacuated from the building in a safe manner in case of fire or emergency. According to the architectural structure of the system buildings, the fire exit corridors and the areas where the fire doors are located, point-by-point announcement units are installed according to their architectural and constructional features and a direction-description announcement about the evacuation point is recorded. Audio descriptions should be concise '' Emergency exit is here '', '' Door is here '', '' Exit is here '' Voice and light announcement device and emergency announcement system are generally confused with each other. Voice alarm provides announcement to be heard at all points of the building The audible, illuminated emergency routing fixture, on the other hand, enables the emergency exit door to be reached point by point by following the sound with a sound announcement that increases as it approaches the door. What is Disabled Sound and Light Emergency Exit Guidance? How to Integrate Sound Lighted Emergency Exit Guidance System in Existing Buildings? For All Our Disabled Audio Light Guidance Products
- Elektrikli Güvenlik Kilitleri | Platin Teknoloji
elektrikli kilit , kilit karşılığı , manyetik kilit , selenoid kilit ile etkin geçiş kontrol çözümleri Electric Safety Locks The access control system is used to monitor the entrances and exits of the people, to limit the rooms they will use in the building, to track and report the movements of the users. It is made of various materials that need to be controlled. Effective electric lock solutions for Steel, Glass, Aluminum, Sheet, Wood, Decorative doors Magnetic Locks Metal doors, glass doors, which are desired to be electrically controlled, are products that will be effective solutions for heavy or sensitive doors. Effective locking with up to 500 kg holding force Electric Strikes They are products that will be effective solutions in areas in doors made of materials such as aluminum and wood, which are desired to be electrically controlled. Electromagnetic Locks Double-sided doors are the solution for locking automatic mechanism electric doors when they are out of use. Cabinet, Cabinet Locks It is the ideal locking solution for cabinet, drawer, showcase and cabinet doors and for doors that do not require high holding force. Due to its much smaller size compared to standard locks, it allows it to be used in places where other locks cannot be applied. Panic Bar Type Lock Striker It is designed to be used with panic bars used in fire and emergency exit doors. It is an effective electric locking solution. Electric Door Opening and Closing It is the solution for automatic electrically opening and closing of existing doors. Doors can be used without contact. High Security Lock Striker Suitable for steel and aluminum doors that are used extensively and require high security striker solutions. Sliding Door Type Electric Locks Effective safe lock solutions for the control of sliding doors that are difficult to control electrically

























