top of page

Site Search Results

253 items found for ""

  • Duman Tableti Nedir | Platin Teknoloji

    What is Smoke Tablet? Smoke tablet offered as a solution for ventilation installation, chimney, sealing, odor test and smoke evacuation equipment testing that require artificial smoke in the environment. It has a structure that will provide the necessary intense smoke quickly. . With the intense smoke obtained, impermeability and device performance tests can be performed easily. . Smoke Tablet / Cartridge / Generator: It defines the test apparatus produced for chimney draft test, which emits smoke without creating flame and soot when burned. Smoke Tablets 45 second smoke tablet (Available in Stocks) 10 cartridges / box Smoke Color: white weight approx: 3 g / cartridge Size approx: 32 x Ø 14 mm Smoke Volume approx: 2,5 m³ Burning time approx: 45 sec. Compliant to BS 5440-1, Ds 675, Test Method ISO 5659-2. Use for testing: Smoke Alarms, Air Filters, Hoods, Air Balancing, Fans, Photography, Special Effects and much more. Not used in sensitive environments, contains large amounts of chloride 90 second smoke tablet (Special order) Allows to produce smoke in use 150 second smoke tablet (Special order) Allows to produce smoke in use 240 second smoke tablet (Special order) Allows to produce smoke in use 300 second smoke tablet (Special order) Allows to produce smoke in use Smoke Cartridges features Cartridges made of environmentally friendly plastic. Moisture-sealed smoke pellets. Reinforced base for minimal heat transfer. There are only smoke pellets made of high-content chemicals. It is guaranteed for 3 years from the date of delivery. Contains no zinc, rubber powder or mothballs. More than 250 security tests have been carried out. There is a warranty mark on the bottom. Comes in a consumer pack or large pack. Fume Tablet Usage Areas Energy Saving insulation test Ventilation Channel Test Draft Test Leak detection Security tests Negative Pressure Chambers Positive Pressure Rooms Fume Hoods Exhaust fans Stage and Screen Effects Photo Effects Air Balancing test Filtration Test Dust Removal Systems Fire and Smoke Alarm Test Poultry and Livestock Education Heat Exchangers Tanks and Piping Kitchen Hoods Electronic Air Filters Asbestos Reduction Radon Reduction Mechanical system risk management. Waste Treatment Systems

  • Madencilik | Platin Teknoloji

    Our Special Solutions for the Mining Sector We offer electronic solutions to the security risks that will occur in all processes from mining, transportation, storage to processing. FIRE DETECTION AND WARNING SYSTEM: Controlling all points of the mine against the risk of fire, such as closed open areas, mines, tunnels, etc., enables the detection of the first occurrence of the fire in the form of particles and to intervene in the fire before it grows. For this purpose, the fire alarm systems installed by Platin Teknoloji prevent the life-threatening of the personnel in the environment and material damage to the building. The system includes a fire control panel. It evaluates the warnings coming from various type detection elements suitable for the needs of your business and activates the sirens, flashers, telephone dialer. It delivers detailed information to the call center and security point. While all these events are happening, from the moment the fire is detected, it is ensured that the previously prepared alarm scenarios are activated by sending information to the elevator, ventilation system, pressurization fans, smoke evacuation system, turnstiles, etc. CLOSED CIRCUIT CAMERA SYSTEMS: Camera systems used to minimize the security and operational risks specific to your needs of mining facilities produce indispensable solutions for operational safety. We offer i camera solutions and DVR, NVR recorder and command control center solutions suitable for all business and manufacturing conditions. Our products do not only register. It produces alarm scenario solutions in order to prevent the occurrence of events, problems and risks by performing event analysis. DETECTION OF FLAMMABLE, EXPLOSIVE AND TOXIC CHEMICALS AND GASES: Gases used in various processes in mines and operating facilities, chemicals, gases generated during manufacturing, or concentrations of gases emitted in storage areas pose a risk in terms of worker health and workplace safety. causes damage. Platinum technology engineers offer customized solutions for your business to identify these risks caused by industrial gases and to evacuate them before the risk grows. FIRE DETECTION WITH VERY SENSITIVE AIR SAMPLING AND ANALYSIS SYSTEMS: The system ensures that the sensitive laser sensor, which continuously samples air from the environment, follows the quality of the air passing through the sampling room and ensures that the fire is detected at the moment of its occurrence. LASER TYPE FIRE DETECTION AND SMOKE DETECTION EQUIPMENTS: At points where high ceiling point type fire detection systems do not work efficiently, laser beam detectors are used to minimize operational and installation costs, economic and fire risks. The system ensures that the fire is detected at the time of its first occurrence by mutually controlling the beam of light it generates. ELECTRIC PANELS AUTOMATIC FIRE EXTINGUISHING: Cabin-type extinguishing systems that provide low initial investment and operating costs and high performance are used for electrical panels and cabinets where risks are concentrated. It provides effective extinguishing with HFC227ea and HFC125 etc. extinguishing gases used in fire extinguishers. They are odorless, colorless, non-residual gases that do not harm electrical material. WATER MOISTURE DETECTION AND ALARM SYSTEMS: These are the solutions to prevent damage to the facility as a result of leakage and humidity that will occur outside the control of the water used in mining areas, Detection of possible floods, Warnings of the relevant parties and the water discharge engine, heating system, ventilation system in accordance with the scenario prepared. AUTOMATIC FIRE EXTINGUISHING SYSTEMS: Process-specific risks that will cause significant damage to the enterprise and solutions that will extinguish electrical fires in a very short time are offered, Automatic extinguishing systems that will prevent damage to the business and manufacturing processes. The relevant extinguishing gas / chemical is selected and designed, taking into account the special situation of the establishment and the area where it will be established. The system user will make independent fire detection and initiate the extinguishing process. CONVEYOR TUNNEL MINE FURNACE PANELS, VENTILATION SYSTEMS FIRE DETECTION AND DETECTION SYSTEMS: With the special sensor cable to be installed in high risk and difficult to detect areas such as conveyor, electrical installations and ventilation ducts, sudden temperature changes are detected at the points where it is located, and fire is detected before it occurs. Linear Heat Detection is a versatile and economical fire detection product. Considering the initial investment, maintenance, operating costs and operating performance, .Extrem offers economical and performance solutions for fire detection needs. ACCESS CONTROL SYSTEMS: We offer solutions for the employees to act in a controlled and safe manner within the enterprise and to control and report the entrance to the designated areas. The doors of risky rooms are controlled with the access control system due to the determined business, safety, hygiene and occupational safety needs. We offer solutions such as personnel card, fingerprint, eye recognition, etc. at the entrances to these rooms. Access control application covers all determined areas starting from the first entry point of the enterprise. It is possible to report all movements and to make the necessary controls online. TURNSTILE AND BARRIER SOLUTIONS: Operation and process entrances are arranged and limited with turnstiles used in integration with the access control system in all areas where the human traffic in the enterprise must be controlled. Thus, it is used for the purpose of controlling the passages at the points and places where the transition should be made within the order determined by the factory. All of our turnstiles are microprocessor-based and allow only one person to pass at a time. Turnstiles have automatic falling arm feature and illuminated and audible indicators. INTELLIGENT CAMERA SOFTWARE: It is not possible to interpret and monitor the environmental security, occupational safety, etc. needs specific to mining enterprises with existing cameras and observations of the operators. Due to all these needs, image - event analysis software has been developed to interpret the images taken from Platin Technology cameras and enable the operation of previously determined factory-specific scenarios. In the Image - Event Analysis software algorithms, images are viewed simultaneously and live, and the software also interprets events and runs scenarios. The software works 24/7 365 days in all environmental conditions. It does not require manpower and equipment. Early fire detection can be achieved with new generation smart thermal cameras. SYSTEM ROOM MONITORING AND REPORTING SOLUTIONS: It has been developed for important technical rooms to operate without risk. It monitors the criteria such as heat, humidity, fire, smoke, network-ups voltages, unauthorized entry etc. of special rooms such as system rooms and ensures that the relevant persons are warned and reported without a possible detection. In addition to the ability to monitor system parameters, it provides integration with other systems in case of an event. In cases of sudden temperature increases and decreases, ups and network voltages, water and humidity raids, unauthorized entry, etc., the system room provides a warning in the form of e-mail or SMS. In this way, the alarm & technical malfunction that caused the error is detected as soon as possible and effective and fast measures are taken. FIRE DETECTION AND ALARM SYSTEM TEST EQUIPMENTS: Testing and regular maintenance of fire detection system equipment established by making serious investments in enterprises are among the overlooked needs in our country. Platin Technology has offered suitable test gases, cleaning and control apparatus for all detector types such as smoke, heat, gas and carbon monoxide, which make up the fire detection system, to the use of professional operating and fire system maintenance companies. EMERGENCY ROUTING LUMINAIRES: In the event of a power outage in the industrial facilities, such as the city network or similar power failure, for safety reasons such as fire, earthquake, interruption of the electrical energy of the building or structure for safety reasons, for automatic activation and evacuation in case of failure of normal lighting due to the opening of a circuit breaker or fuse are devices and systems that direct users. EMERGENCY ANNOUNCEMENT AND SOUNDING SYSTEM: Emergency announcement and sounding systems in industrial facilities are the solutions used for the rapid evacuation and guidance of the employees in the buildings in emergency situations and safely. KEY MANAGEMENT SYSTEMS: It is ensured that keys of all areas and vehicles belonging to the enterprise can be easily accessed when necessary, and key management solutions are prevented and securely protected with key management solutions that ensure the reporting of key usages. SECURITY AUTOMATION SOLUTIONS: It installs security automation systems against theft and sabotage in medium and small type projects. These systems, which are needed today, are the definitive solution to robberies and unauthorized access. The possibility of false alarms of these systems is very low and they provide the opportunity to intervene in the system only with the correct password. There are products and systems with different detection features in security systems according to the purpose and protection system. Electronic systems are integrated with alarms, where the necessary precautionary warnings are activated instantly and the security risks of large-scale areas such as Shopping Center, Plaza, Headquarters, Factory, Campus are minimized. It offers solutions to minimize risks in all areas of the mining industry. Please contact us for special solutions for your projects in Turkey and all countries in our service area.

  • Yaslı ve Engellilere Yönelik  Evde Panik Buton Sistemi Platin Teknoloji

    Elderly Support, Home Care Automation System Home Care; Effective care and safety automation for Elderly, Sick and Handicapped individuals living alone or in need of care at home. Automation solutions for public institutions and municipalities that provide disabled and elderly support services: Elderly and disabled individuals living alone in their homes; Monitoring health conditions in digital environment Informing the relevant health authority when necessary Ensuring the safety of elderly people Meeting the personal needs of elderly people Supporting elderly people to live in their homes We offer electronic solutions to increase the quality of life and ensure their social integration. What is Followed in Home Care Service. Health Risks Pulse Temperature Fall Don't leave the house Asking for help with a panic button Security Risks Fire, smoke, Gas detection Anti-theft alarm Water and flood alarm Social help Follow-up of social service needs such as cleaning, food, etc. How does it work Disabled, Sick, Elderly person communicates with the center by pressing the button whenever deemed necessary with the portable wristband or necklace type and the panic button. The conversation starts with the call center operator as soon as the button is pressed, and bidirectional communication is provided in this way. It can be provided in conversation with the hands-free microphone and speaker on the panel. Panic button also measures body temperature, (Optional Pulse, oximeter and fall sensor) alarm scenarios continue to function just like when the panic button is pressed, in case of exceeding the specified level; At the same time, this information reaches the call center in parallel, and the process is followed, confirmed and reported simultaneously; Application user can be backed up in parallel. The system is open to developments. It can add suitable new generation medical devices. TECHNICAL SPECIFICATIONS 7/24 Professional monitoring and control Two-way voice conversation via GSM connected panel Panel touch and voice guided Functional emergency buttons on it Panel communicates centrally with TCP / IP over 3G or GPRS 869 MHZ wireless communication with panel equipment Parallel alarm center connection Meeting with the center in case of emergency by means of a button Informing the center automatically in case of violation, detection and alarm Periodic communication test signal Waterproof and long battery life pan button Measuring body temperature via panic button Alarm sending over 38 ' Tracking via mobile application Drug programming via mobile application Tamper, low battery, communication error notification Backup battery against power outages Suitable for wall mounting or desktop use Warning against dismantling and sabotage EN 50131 Grade 2 compliant Wireless security equipment support OPTIONAL FEATURES Drop sensor Heart rate sensor Oxidation sensor It is the system features known as the emergency call panic button for the elderly in the society. FOR OUR OTHER ELECTRONIC ACCESSIBILITY SOLUTIONS

  • Yangın Algılama Sistemi Test Ekipmanları | Platin Teknoloji

    Fire Detection System Test Equipment '' Test your fire detectors, make sure they work '' '' Clean it for many years without problems '' Solo A10 Smoke Detector Test Aerosol All fire detection systems approved by smoke detector manufacturers Solo A10 is preferred by professionals for fire detector testing, thanks to its structure similar to real fire smoke. More information Solo A5 Smoke Detector Test Aerosol Solo A5 smoke detector test sprays, approved by all fire detection system smoke detector manufacturers, provide functional and efficient tests. Solo A5 is preferred by professionals due to its structure similar to real smoke in its content. More information Solo C3 CO Test Spray Detection cells of carbon monoxide (CO) detectors, such as fire detection equipment, must be tested in accordance with international rules and standards. Solo C3 has been produced for this purpose. More information Solo 811 Smoke Detector Test kits With Solo test kits, it is possible to supply and use all equipment as a set. In this way, testing, detector disassembly and assembly operations can be carried out easily in areas with high ceilings. More information Smoke Saber Smoke Test Spray Smoke Saber contains a new generation of major changes in the design of smoke detector testers. All other pressurized aerosol smoke test sprays have disadvantages as they leave harmful residue in the detector's chamber and / or casing. More information Solo 365 Next Generation Smoke Detector Test Equipment New Generation test equipment Solo 365 produces test smoke, wastes less smoke during testing and provides more tests than conventional smoke sprays More information Solo 460 and 461 Heat Detector Test kits You can easily test temperature detection type detectors with solo test kits. In this way, testing, detector removal and mounting operations can be carried out easily in high ceiling areas. battery powered More information Smoke Test Tablets Smoke test tablets offered as a solution for the test of smoke evacuation equipment such as ventilation systems, chimneys, etc. that require artificial smoke in the environment. It has a structure that will provide the necessary intense smoke quickly. . With the intense smoke obtained, impermeability and device performance tests can be performed easily. . More information Solo 423 and 424 Next Generation Temperature Detector Test Equipment You can easily test temperature detection type detectors with solo test kits. In this way, testing, detector removal and mounting operations can be carried out easily in high ceiling areas. Works with 110 / 120 or 220 / 240 volts More information

  • eaton | Platin Teknoloji

    EATON Fire Detection, Warning and Alarm Systems Eaton offers you its expertise in the development of fire alarm systems based on strong heritage from names such as Cooper, Menvier, JSB, Nugelec and Fulleon. Eaton works with industry-leading organizations as well as its customers to meet the highest standards; It has increased its recognition globally with its products that you can see in many places such as stadiums, multi-storey buildings, government buildings, airports, bus terminals, train stations, hospitals, nursing homes, industrial facilities, retail outlets and social facilities. Eaton; produces market leading addressable and conventional fire alarm systems that are compatible with specific application requirements, efficient, user-friendly and can be configured according to specific applications. Eaton offers complete complete fire system solutions and manufactures all of its products. You can safely use it as a completely complete fire detection and alarm system, as all system components are fully compatible with each other. All equipment complies with international standards and this conformity is certified. It is absolutely vital that all elements of the fire detection system are fully compatible with each other. To support this philosophy, our large multidisciplinary research and development team based in Doncaster is responsible for integrating the latest technology into Eaton's Fire Systems Business range. Eaton's fire systems business products have international approvals, the CF3000 and CF1000 series are Europe's first touchscreen analog fire panels available in 27 languages at your fingertips. Cooper Eaton Fire detection systems Turkey-wide solutions at Platin Teknoloji. Eaton Philosophy Investing in people Partnering with our clients to develop open, long-term relationships Have an unpretentious, open and honest approach to the business Continuous investment in research and development Investing in production facilities to keep them at world standards To produce products that fully comply with the standards Working environmentally - in the products we design and the facilities we make them To have high ethical standards eaton complies with standards. EN 54 CF1100VDS Electronic Addressable Fire Alarm Control Panel - 1 Loop, 200 Address Capacity, Touchscreen LCD Display, 16 Zone LEDs, 2 Siren Outputs, Power Supply CF1200VDS Electronic Addressable Fire Alarm Control Panel - 2 Loops, 400 Address Capacity, Touchscreen LCD Display, 16 Zone LEDs, 2 Siren Outputs, Power Supply CF2000GCPD Electronic Addressable Fire Alarm Control Panel - 2 Loops, 400 Address Capacity, LCD Display, 32 Zone LEDs, 2 Siren Outputs, Power Supply, Non-Networkable CF30002G Electronic Addressable Fire Alarm Control Panel - 2 Loops, 400 Address Capacity, Touchscreen LCD Display, 96 Zone LEDs, 4 Siren Outputs, Power Supply CF30004G Electronic Addressable Fire Alarm Control Panel - 4 Loops, 800 Address Capacity, Touchscreen LCD Display, 96 Zone LEDs, 4 Siren Outputs, Power Supply CTPR3000 Full Function Repeater Panel, LCD Touch Screen, Network Connection with CF3000 and CF1000 Series Control Panels CAP320-EU Electronic Addressable Optical Smoke Detector, Internal Short Circuit Isolator CAPT340 Electronic Addressable Combined Optical Smoke and Heat Detector with Internal Short Circuit Isolator CAH330-EU Electronic Addressable Constant Temperature and Temperature Rise Rate Detector with Internal Short Circuit Isolator CBG370S Electronic Addressable Fire Alarm Button with Internal Short Circuit Isolator CBG370WP Electronic Addressable Manual Call Point with Internal Short Circuit Isolator, Outdoor Type IP65 CSI350 Loop T-Connection Module CIO351 Electronic Addressable, Independently Programmable 3 Channel Input / Output Module with Internal Short Circuit Isolator (Reset during reset) CIO351S Electronic Addressable, Independently Programmable 3 Channel Input / Output Module with Internal Short Circuit Isolator (Resets during Alarm Silencing) CFC301 3-Channel Technical Input / Output Interface Unit CZMU352 Electronic Addressable Zone Supervision Module with Internal Short Circuit Isolator CMIO353 Electronic Addressable, Single Channel Input / Output Module, 230V AC Relay Output, with Internal Short Circuit Isolator CSC354 Electronic Addressable, Independently Programmable 4 Output Sounder Control Module, Internal Short Circuit Isolator, Power Supply CAS380 Electronic Addressable Socket Type Electronic Siren, 95dB, With Internal Short Circuit Isolator CASBB384 Electronic Addressable Socket Type Flasher Electronic Siren With Internal Short Circuit Isolator

  • Yangın Algılama , İhbar  ve  Alarm Sistemleri | Platin Teknoloji

    Fire Detection, Warning and Alarm Systems With fire detection systems designed by Platin Technology specialists, controlling all points of the building in the workplaces, houses, factories and shopping malls where people live and work, and in workplaces, houses, factories and shopping centers that they have with serious efforts. It allows to be given. For this purpose, the fire alarm systems installed by Platin Teknoloji prevent the life-threatening of the people in the environment and the material damage of the building. FIRE DETECTION SYSTEMS. WORKING PRINCIPLE OF SENSING SYSTEMS The system has a fire panel. The panel evaluates the warnings coming from various types of sensing elements and activates the warning elements (sirens, flashers, telephone dialer). In the new generation systems, from the moment of fire detection, it sends information to the elevator, ventilation system, pressurization fans, smoke evacuation system, turnstiles, etc., and ensures that alarm scenarios are activated. Fire Detection Systems are evaluated in two separate sections in terms of working principle. 1- Conventional Fire Detection Systems: The detection panel used in the system consists of areas where the detection elements are connected. The number of zones is related to the capacity of the panel. 20 detectors can be connected to each zone. The panel also has inputs and outputs to which fire alarm buttons and sirens will be connected. When any detector detects or when the fire alarm button is pressed, a warning signal comes from the zone in which the said detection element belongs on the panel. For example: When any detector detects in an area to which 20 detectors are connected, a warning will come from that area. (But it will not be clear from which detector the warning is coming from.) 2- Addressable Fire Detection Systems: In addressable systems, there are loop lines to which sensing elements are connected. The number of loop lines and the wiring distance depends on the panel used. 125 -127 addressed elements (detector, button, input module, output module, addressed siren) can be connected to a loop line. Sensing elements in the loop can be divided into zones and each sensing element can be individually perceived by the panel thanks to the addressing software it contains. In other words, when any detector detects, the location of the detector can be determined individually on the panel or on the pc where the projects of the building, which can be used optionally, are loaded. Conventional systems and addressable systems are selected and sized according to their application locations. Conventional elements are sufficient for systems with a small number of sensing elements and offer cheap solutions. Advantages of addressable systems 1- In addressable systems, clear information of the location of the detector where the information such as alarm, malfunction etc. comes from can be reached. In conventional systems, region (floor) information comes. The net location of the detector must be checked for the region. 2- In addressable systems, alarm, error, loss, malfunction and calibration information of the detectors are displayed on the panel as a point. 3- In addressable systems, 127 equipment can be operated on each cable line. This number is limited to 20 detectors in conventional systems. 4- In addressable systems, the system continues to work in the problem of the wiring line, providing information about where the problem is. In conventional systems, the part after the line is completely disabled. 5- Equipments such as input module, output module, siren module etc. from addressed systems can operate over the loop line. In conventional systems, general alarm and error information can be received from the panel. 6- In addressable systems, wide range of alarm scenarios that will be activated in case of fire can be applied. Our Fire Alarm System Brands We Offer to the Turkish Market - GE-UTC Kilsen - UK - GE-UTC Ziton - UK - GE-UTC ARITECH - ENGLAND - GE-UTC GST - CHINA - DETNOV - SPAIN - GLOBAL - PORTUGAL - COOPER - ENGLAND - SIEMENS - AMERICA - APOLLO-UK Frequently Asked Questions ​ Does incense trigger the fire alarm? Does the alarm go off? Since there is a fire detection equipment in the area where you are using incense, this question must be on your mind. In today's conditions, many people still live in buildings without fire safety measures. It means . According to many people, you are lucky in terms of life safety. Know your worth! The answer to your question is that it is not possible for the fire detector to distinguish between the smoke produced by the incense and the difference that occurs during the formation of the fire. Considering that there are many different types of incense in terms of content and that even the smallest smoke emits serious smoke, "incense activates the fire alarm" and provides protection for your life by doing the fire alarm function. ​ How do we know if the smoke detector is working? It is the duty of the technical team to understand that the smoke detector , which is one of the main elements of the fire detection system, is working, to keep it running and to perform the necessary maintenance. If you see a smoke detector somewhere, it is the legal duty and responsibilities of the administrator to keep it running and to perform the necessary maintenance. In summary, if you see a smoke detector, it is in working order. It is legally a crime and a conscientious responsibility to remove and remove it, to put some barriers to prevent the smoke from reaching. ​ How to turn off the smoke sensor ? Turning off the smoke sensor increases the risk of damage in a possible fire and is legally a crime. It is mandatory to keep fire detectors operating 24/7 from the moment they are installed in the building. ​ How to turn off smoke detectors in hotels? If your aim is to turn off the smoke detector and smoke, please head to the areas suitable for smoking , which will not pose a risk, we recommend that you consider that the majority of fires in hotels are caused by cigarette butts. ​ Why does the fire detection system beep? By detecting smoke, heat, etc. detectors in the system or pressing the manual alarm buttons, the fire detection system sounders are activated. ​ ​

  • Aritech Yangın Algılama Dedektörleri | Platin Teknoloji

    Aritech Fire Detection, Warning and Alarm UTC Arıtech, one of the flagship brands of UTC Carrier Fire & Security 'family, is in Turkey !! Platin Teknoloji service difference Why should the Aritech fire detection system be preferred? Fire detection and alarm system is the most important protection solution for the safety of life and property in all businesses, whether small or large. A failure in the system can pose a danger at a level that can endanger the entire investment. Knowing these problems and responsibilities, Aritech produces solutions with its long years of experience and products in accordance with world standards. Helps protect investments and human life. It has combined this solution partnership with platinum technology expertise in Turkey. Thanks to fast installation and commissioning, easy maintenance and outstanding modern design, 2X Series fire panels are appreciated by technical personnel, installation personnel, architects and investors. Aritech Fire Alarm Systems Distinctive Features Simple and convenient front panel control Fast system setup and configuration Increased automatic programming feature • Undo last changes feature Offline programming and ability to upload configuration file to USB device Easily configurable preferred cards and modules Remote maintenance and error detection over TCP / IP Up to 72 hours of standby time Graphical EN54 compliant icon supported LCD display Easy to change language options Surface / flush * / 19 ”rack * mounting It offers superior performance features from single panel applications to applications requiring small / medium sized networks. Aritech 2X-Intelligent Analogue Addressable Fire Detection Panel 2X-F1-19 Intelligent Addressable Fire Alarm Panel - 1 loop (Turkish) 2X-F2-19 Intelligent Addressable Fire Alarm Panel - 2 loops (Turkish) 2X-FR-19 Intelligent Addressable Fire Repetition Panel (Turkish) 2X-LB Loop expansion board - 2 loops 2010-2-NB Network Card 2X-ZI-20 LED Indicator Screen - 20 Zone 2X-ZI-40 LED Indicator Screen - 40 Zone Optical Smoke Detector DP2061N Addressable Optical Smoke Detector, Double LED, Remote Output DP2071 Addressable Optical Smoke Detector, 7-segment display, Remote Output Heat Detector DT2063 Addressable Heat Detector, Double LED, Remote Output DT2073 Addressable Heat Detector, 7-segment display, with Remote Output Combined Detector DP2061T Addressable Combined Detector, Optical / Heat Detector Base DB2002 Standard Detector Base, 4 Terminals, Grounded - 100mm DB2016 Insulator Base Sounder Detector Base AS2368CAP-R Locking Cover for DB2368 Sounder Base, Red AS2368CAP-W Locking Cover for DB2368 Sounder Base, White LED Indicator AI672 LED Indicator AI673 LED Indicator with Buzzer Fire Alarm Button DM2010 Addressable Manual Call Point, Red, Surface Mount (Glass Included) DM2010E Addressable Outdoor Fire Alarm Button, Red, Surface Mount (Glass Included), IP67 Control-Monitoring (Input / Output) Modules IO2014C Addressable Control Module - 4 Inputs (Including mounting box) IO2031C Addressable Control Module - 2 Inputs / 1 Output (Including mounting box) IO2032C Addressable Control Module - 2 Inputs / 2 Outputs (Including mounting box) IO2034C Addressable Control Module - 4 Inputs / 4 Outputs (Including mounting box) IU2050C Addressable Control Module - 1 Input (Including mounting box) IU2055C Addressable Control Module - 2-wire Zone Monitoring (Including mounting box) IU2080C Addressable Control Module - Siren (Including mounting box) IO-2BOX Assembly box ISM-95 Isolator Module (Including mounting box) Loop Powered Siren and Warning Equipment AS2363 Loop Powered Siren, 32 Different Tones, Shallow Base, Red AS2363W Loop Powered Siren, 32 Different Tones, Shallow Base, White AS2364 Loop Powered Siren, 32 Different Tones, Deep Base, Red AS2364W Loop Powered Siren, 32 Different Tones, Deep Base, White AS2366 Loop Powered Sounder / Beacon, 32 Different Tones, Shallow Base, Red AS2366W Loop Powered Sounder / Beacon, 32 Different Tones, Shallow Base, White AS2366WY Loop Powered Sounder / Beacon, 32 Different Tones, Shallow Base, White / Amber AS2367 Loop Powered Sounder / Beacon, 32 Different Tones, Deep Base, Red AS2367W Loop Powered Sounder / Beacon, 32 Different Tones, Deep Base, White AS2367WY Loop Powered Sounder / Beacon, 32 Different Tones, Deep Base, White / Amber

  • İşitme Engelli için Sesli ve Işıklı Flaşör  Acil Uyarı  Sistemi | Platin Teknoloji

    Audible, Illuminated Emergency Warning System The use of sound and light sirens to warn individuals with no disabilities and especially hearing / hearing impaired individuals in emergency situations is described in accessible project implementations and fire regulations. Sirens and Flashers have been developed with many years of experience and a series of R&D studies for the necessary signaling in order to provide the necessary warnings in case of emergency evacuation and fire detection. It is an effective and accessible evacuation solution for the hearing impaired individuals by turning the sirens of the fire system, which is active in situations requiring emergency evacuation, such as fire, water - flood, earthquake, terrorist incidents, etc. The new generation audible light siren and alerts produce pulse type sound specially produced for fire detection systems. Fire signs and siren signs emit pulsating light, complying with a new European standard EN54-23 for high brightness visual alarm devices. Using light, Sonos Pulse marks reach those who are audiably perishable, or workers in noisy environments, to provide effective evacuation. Patented Pulse Alert Technology distributes light evenly, providing maximum coverage with less consumption. Sonos Impact devices are designed to fulfill evacuation requirements in most rooms with just one device to reduce costs and increase energy efficiency. Sonos Impact devices are a simple process in most environments, with upgrading existing systems to new EN54-23 compliant versions using the same base connections to previous models Pulse Alert Technology; Pulse Alert Technology is a new beacon alert system that produces a light output that can protect most rooms with just one device. Ensuring the most efficient distribution of light, distributing light evenly in order to maximize the effectiveness of new optical systems. The new LED lighting technology is derived in automotive applications, with a Pedigree proven for reliability and performance in the harshest environments. The patented electronic design maximizes electrical efficiency, reducing current consumption to minimize the cost of ownership and allowing more devices to be installed in a single alarm system. Impact Alert Technology EN54-23 compliant system while doing this, design challenges bring all the answers, bring benefits. The flash intensity and frequency of combined devices that warn with light with additional flashes to the siren are described in EN 54 in a way that they do not affect patients who are sensitive to light. If the building is used for housing, hotel, etc. purposes, additional measures should be taken for individuals with hearing impairment. FOR OUR OTHER ELECTRONIC ACCESSIBILITY SOLUTIONS

  • Products | Platinum Technology

    Platin Technology Products and Solutions You can find detailed information about our Electronic Security solutions and alternative solutions here. Platin Teknoloji offers electronic solutions specific to your security risks. You can find detailed information here, review our wide range of products and get support from our experts. For more information You can find our electronic solutions for worker health and safety here. You can find our solutions for worker health and business safety here. You can find solutions specific to your business needs from Platinum Technology Experts. For more information We offer electronic accessibility solutions for barrier-free living Access to all electronic accessibility solutions required for disabled and non-disabled individuals to participate in social life without the need for individuals. You can get support from Platin Technology experts. Platin Teknoloji, which is one of the first to implement the Platin Technology Consultant vendor work in our country, Platin Technology experts provide Security, occupational health and Accessibility solutions for all areas, businesses and professional groups.

  • Yangın Algılama EXTREM Çözümleri | Platin Teknoloji

    FIRE DETECTION SYSTEM EXTREM SOLUTIONS Yangın Algılama EXTREM Çözümler: Markalar We offer early fire detection solutions in areas that are difficult to resolve with conventional fire alarm equipment. Laser Fire Detection Beam Detectors Optical Beam Smoke Detector is used to provide "wide area" smoke detection. These are generally practical. Traditional point type detector is used in environments where installation and operation is difficult. (installation, wiring and maintenance) It also provides wide coverage at low cost. Optical Beam Smoke Detectors are ideal for high ceilings, dusty and dirty environments, or you may encounter extremely hot environments. Air Sampling Precision Fire Detection Systems Very sensitive air sampling smoke detectors guarantee the high performance you need in all kinds of applications where it is difficult to detect smoke with conventional methods and the results are not sufficient. Sensitive and stable fire detection is possible with laser detectors, whether it is very clean, very dirty, very high, or very narrow and inaccessible. Cable Type Fire Detection Systems Linear Heat Detection is a versatile and economical fire detection product. Designed for use in a wide range of fire and heat detection applications where maintenance access is in the physical or hazardous area and / or where there is a requirement that cost-effective fire detection is near danger, Linear cable is suitable for harsh environmental conditions. Wireless Fire Detection, Warning and Alarm Systems It is used for the detection of fire and wireless operation of all necessary equipment in places such as museums, historical artifacts, Yali, etc. It has been implemented in many projects throughout Turkey and its excellence has been registered. Although all equipment works with batteries, batteries are long-lasting. The panel and all equipment in the field provide two-way communication online. Apart from the alarm information, information on pollution, battery level, communication status can be followed online. Early Fire Detection and Alarm Solutions with Thermal Camera As of 2019, VDS has deemed it suitable for use of thermal cameras for early fire detection solutions in difficult and risky areas. A panoramic heat map is created in the thermal camera risky area. Operational temperatures are determined separately for each point on this map. The heat map is updated instantly and the detection scenario starts to be applied in case the temperature changes exceed the determined limits. In this way, fire is detected before it occurs. Fire Detection System Test Equipment Testing and regular maintenance of fire detection system equipment established by making serious investments in enterprises are among the needs that are ignored in our country. Platin Technology has offered suitable test gases, cleaning and control apparatus for all detector types such as smoke, heat, gas and carbon monoxide, which make up the fire detection system, to the use of professional operating and fire system maintenance companies. EN 54 4 Certified Power supplies In the fire detection system integration applications, the need for the increasing use of power supplies that feed all equipment included in the system and the EN54-4 compliance requirements of all equipment included in the fire detection system, UPS function power supply with battery charging feature has arisen. Cigarette-Tobacco Smoke Detection and Alarm Solutions We offer cigarette smoke detection and alarm system solutions with detectors that detect the smoke of products that are prohibited, harmful to health and pose a risk to use in businesses. Early Fire Detection and Alarm Solutions with Thermal Camera As of 2019, VDS has deemed it suitable for use of thermal cameras for early fire detection solutions in difficult and risky areas. A panoramic heat map is created in the thermal camera risky area. Operational temperatures are determined separately for each point on this map. The heat map is updated instantly and the detection scenario starts to be applied in case the temperature changes exceed the determined limits. In this way, fire is detected before it occurs.

  • İş Merkezleri ve Plazalar | Platin Teknoloji

    Headquarters, Plazas, Work centers, multi-storey buildings and for plazas electronic security solutions Our experts, who offer special solutions for General Directorates, Plazas, Business centers, Multi-storey buildings and plazas where there are thousands of people and visitors at the same time, where institutions, organizations and companies are common, offer the solutions below for multi-storey plaza and office buildings. FIRE DETECTION AND WARNING SYSTEM: Control of all office, administrative, mechanical areas and parking lots of the plazas against fire risk.It provides instant detection of the first formation of the fire in the form of particles and allows the fire to be intervened before it grows. For this purpose, the fire alarm systems installed by Platin Teknoloji prevent the life-threatening of the personnel in the environment and material damage to the building. The system includes a fire control panel. It evaluates the warnings coming from various type detection elements suitable for the needs of your business and activates the sirens, flashers, telephone dialer. It delivers detailed information to the call center and security point. While all these events are taking place, from the moment the fire is detected, it is ensured that the previously prepared alarm scenarios are activated by sending information to the elevator, ventilation system, pressurization fans, smoke evacuation system, turnstiles, etc. CLOSED CIRCUIT CAMERA SYSTEMS: Camera systems, which are used to minimize the risks in indoor and outdoor areas and special security and operational risks within the boundaries of the plaza, produce indispensable solutions for operational security. We offer camera solutions and NVR recording devices and command control center solutions suitable for all business and manufacturing conditions. Our products do not only register. It produces alarm scenario solutions in order to prevent the occurrence of events, problems and risks by performing event analysis. All systems record in the structure and quality determined by the relevant institution and ensure that images of appropriate quality are accessed when necessary. DETECTION OF FLAMMABLE, EXPLOSIVE AND TOXIC CHEMICALS AND GASES: Necessary perceptions are made to minimize the risks caused by flammable explosive gases and chemicals used in the mechanical areas of heating, cooling, etc. of all buildings, and to prevent damage to the personnel and the enterprise. Platinum technology engineers provide customized solutions for your business to identify these risks caused by gases and chemicals and to evacuate them before the risk grows. FIRE DETECTION WITH VERY SENSITIVE AIR SAMPLING AND ANALYSIS SYSTEMS: The sensitive laser sensor, which continuously samples air from the system room, ensures that the quality of the air passing through the sampling room is monitored and the fire is detected at the moment of its occurrence. LASER TYPE FIRE DETECTION AND SMOKE DETECTION EQUIPMENTS: At points where high ceiling point type fire detection systems do not work efficiently, laser beam detectors are used to minimize operational and installation costs, economic and fire risks. The system ensures that the fire is detected at the time of its first occurrence by mutually controlling the beam of light it generates. ELECTRIC PANELS AUTOMATIC FIRE EXTINGUISHING: Cabinet type extinguishing systems that provide low initial investment and operating costs and high performance are used for electrical panels and cabinets where risks are concentrated. It provides effective extinguishing with HFC227ea and HFC125 etc. extinguishing gases used in fire extinguishers. They are odorless, colorless, non-residual gases that do not harm electrical material. WATER MOISTURE DETECTION AND ALARM SYSTEMS: Prevention of damage to the establishment as a result of leakage and humidity that will occur out of control from risky areas for warehouse, boiler room, mechanical areas and building, Detection of possible floods, Warning of the relevant parties and according to the prepared scenario, the water evacuation engine heating system, ventilation system These are the solutions to put into use. AUTOMATIC FIRE EXTINGUISHING SYSTEMS: Special risks such as system room, operational areas, vault room etc. that will cause significant damage to the enterprise and solutions that will extinguish electrical fires in a very short time are offered, Automatic extinguishing systems to prevent damage to the business and manufacturing processes. The relevant extinguishing gas / chemical is selected and designed, taking into account the special situation of the establishment and the area where it will be established. The system user will make independent fire detection and initiate the extinguishing process. CABLE TRAYS, VENTILATION SYSTEMS FIRE DETECTION AND DETECTION SYSTEMS: With a special sensor cable to be installed in high risk and difficult to detect areas such as electrical installations and ventilation ducts, sudden temperature changes are detected at the points where it is located and fire is detected before it occurs. Linear Heat Detection is a versatile and economical fire detection product. Considering the initial investment, maintenance, operating costs and operating performance, .Extrem offers economical and performance solutions for fire detection needs. ACCESS CONTROL SYSTEMS: We offer solutions for controlling and reporting the staff visitor circulation in all areas of the business center. Due to the determined business, security and occupational safety needs, the doors of risky rooms are controlled by the access control system. We offer solutions such as personnel card, fingerprint, eye recognition, etc. at the entrances to these rooms. Access control application covers all determined areas starting from the first entry point of the enterprise. It is possible to report all movements and to make the necessary controls online. The buildings belonging to the enterprise can be controlled and monitored from the same central software wherever they are in the world. TURNSTILE AND BARRIER SOLUTIONS: Building and floor entrances are arranged and limited with turnstiles used in integration with the access control system in all areas where human traffic in the building needs to be controlled. Thus, it is used for the purpose of controlling the transitions at the points and places where the transition should be made within the order determined by the general directorate. All of our turnstiles are microprocessor-based and allow only one person to pass at a time. Turnstiles have automatic falling arm feature and illuminated and audible indicators. SYSTEM ROOM ENVIRONMENTAL MONITORING AND REPORTING SOLUTIONS: It has been developed to ensure that important technical rooms can operate without risk. It monitors the criteria such as heat, humidity, fire, smoke, network-ups voltages, unauthorized entry etc. of special rooms such as system room and ensures that the relevant persons are warned and reported without a possible detection. . In addition to the ability to monitor system parameters, it provides integration with other systems in case of an event. In cases of sudden temperature increases and decreases, ups and network voltages, water and humidity raids, unauthorized entry, etc., the system room provides a warning in the form of e-mail or SMS. In this way, the alarm & technical malfunction that caused the error is detected as soon as possible and effective and fast measures are taken. FIRE DETECTION AND ALARM SYSTEM TEST EQUIPMENTS: Testing and regular maintenance of fire detection system equipment established by making serious investments in enterprises are among the overlooked needs in our country. Platin Technology has offered suitable test gases, cleaning and control apparatus for all detector types such as smoke, heat, gas and carbon monoxide, which make up the fire detection system, to the use of professional operating and fire system maintenance companies. EMERGENCY ROUTING LUMINAIRES: In case of a power failure, especially in multi-storey buildings, in case of a power outage, such as fire, earthquake, the electrical energy of the building or building is interrupted for safety purposes, when a circuit breaker or a fuse is opened, it is automatically activated and evacuated. are devices and systems that guide users for EMERGENCY ANNOUNCEMENT AND SOUNDING SYSTEM: Emergency announcement and public address systems are the solutions used for the rapid evacuation and direction of the employees in the buildings and safely in emergency situations. SECURITY AUTOMATION SOLUTIONS: It installs security automation systems against theft and sabotage. These systems, which are needed today, are the definitive solution to robberies and unauthorized access. The possibility of false alarms of these systems is very low and they provide the opportunity to intervene in the system only with the correct password. There are products and systems with different detection features in security systems according to the purpose and protection system. Electronic systems integrated with alarms are systems in which the security risks of large-scale areas such as Head Office, regional directorate, branch, campus, etc. are minimized by instantly activating scenarios and taking necessary precautionary warnings. KEY MANAGEMENT SYSTEMS: It is ensured that all keys of the common areas in the building can be easily accessed when necessary and key management solutions that enable the reporting of key usages to prevent key confusion and to protect them securely. LIVING SOLUTIONS WITHOUT BARRIERS: These are electronic solutions offered for disabled visitors and employees to meet their daily needs risk-free and comfortably within your business and to minimize possible risks. What are the risks? We offer solutions to the need for help and urgent struggle in wet areas, the need for medical assistance in general areas, and the risks of reaching exits without assistance in emergency evacuation processes. It offers electronic security solutions to minimize the risks of multi-storey buildings, plazas and office areas. Please contact us for special solutions for your projects in Turkey and all countries in our service area.

  • wc yapay su sesi | Platin Teknoloji

    Artificial Water Sound Water Saving Solution in Public Toilets According to the researches, all individuals, both men and women, try to suppress the unwanted sounds from outside and relieve their anxiety by making flushing noise / water sound in public toilets open to public use, thus they try to prevent their faces from reddening when they go outside the WC. The habits of suppressing the sounds in the toilet with the sound created by flushing the faucet, leaving the faucet open or wasting meters of toilet paper cause at least 20 m3 of water and meters of toilet paper. The solution to prevent waste and preventing the sounds inside the WC from being heard from the outside is an artificial siphon, a water sound device. This device is completely domestic production. It can be activated when the car starts to use, when the door is locked or with a manual button. Environmental solutions at Platin Technology

  • Afet ,Toplumsal Uyarı Anons ve Siren Çözümleri | Platin Teknoloji

    Disaster, Social Warning Announcement and Siren Solutions We offer central solutions where possible natural disasters, war situations, terrorist attacks, problems specific to megacities, etc., where the public can be alerted quickly, risk management, sirens and warnings can be delivered centrally. Announcements and sirens to be made can be controlled independently by the scenario to be prepared and the central disaster control unit. Our systems are in a structure that allows it to be controlled from a single center from a small town with 10,000 people to megacities with 20,000,000 people and to the whole country. Our solution partner digitexCZK / IP® system was created based on the latest technologies according to the original design of the PLATAN construction team. This system is one of the first manufacturers to use analog as well as digital radio communications in DMR (TDMA) and NXDN (FDMA) standards, as well as local area and wide area networks (LAN, WAN) and encrypted IP for data transmission. In digitexCZK / IP® system, the use of IP for data and voice transmission makes it possible to easily create and develop the system and existing analog warning systems, eg. It provides integration with digitexCZK / FSK, DSP-50, RSSS 2000/3000, MDSA-24. Implementing a new Digital Human Alert System does not require changing the old one. The existing system can be integrated with digitexCZK / IP®. In case of integration, all sirens, including both new and existing ones (analog), working in the digital standard, are operated from the same distributor desk. Thanks to the use of the computer network and the IP protocol, the operation of the system can be kept at various access levels. digitexCZK / IP® consists of system nodes whose structure is likely to be the same as the hierarchical one existing in Europe. In this case, regional, provincial and district options may be preferred. Each splitter desk in digitexCZK / IP® system is equipped with a PC with digitexCZK / IP® software. The software contains a map of a zone in which all alarm points operating in the system are marked. A distributor can control and test both electronic and electromechanical systems from the map level. In addition, from the digitexCZK / IP® system, it can receive information on the following topics: communication or lack of communication with sirens, supply (main / backup), performing a specific task (activating the alarm, testing), battery level, audio route efficiency, and others. The digitexCZK / IP® system is simple and convenient to use, and all operations are done remotely from the distributor's desk. A part inherent in the digitexCZK / IP® system is the DSE series modern Electronic Sirens. Apart from sound signals, they allow voice messages to be sent live remotely from the management desk or locally with a microphone. Also, DSE sirens can emit any audio announcements (wav or mp3 files) stored in memory. Inside the digitexCZK / IP® system, it is possible to connect measuring transducers and / or actuators (e.g. meteorology stations, gas detectors, contamination detectors, water level indicators, doors, control screens, light signals or combustion gas discharge system, etc.). Advantages of Disaster, Social Warning Announcement and Siren Solutions · Transmission using public or non-public IP networks. · Transmission using digital radio-telephones (providing but not limited to channel capacity, data accuracy, wide broadcast range). · Higher data security: encoding of data in the digitexCZK / IP® system, eg. It is the same coding used in SSL transmissions in banking systems. System architecture with a server at the central point it connects to. There may be several equivalent distributor stations operating within the system and several miscellaneous priority and authorization stations. · Ability to create multi-level systems (no restrictions on the type of floor, region - province - district). · All system configuration data are saved in SQL database on the system server. Low service costs. Convenient operation using an updated program with a map, systematically updating the status of the sirens, all tests of the audible siren route from the database (sound generator, amplifier, conductor, converter) - automatic complete test at a certain time. Systematic reading of data from a siren (door status, power source, battery voltage). · Ability to update siren sounds and software remotely. Compatibility with other manufacturers' sirens and systems. · Increased running speed and system testing. Facility stations and distribution stations · Information about sirens (eg parameters, place and date of installation, responsible party, comments, picture, etc.). · High system scalability. The ability to create both straight hierarchies and vertical structures. · Possibility to connect measuring transducers and / or actuators (eg meteorology stations, gas detectors, contamination detectors, etc.). Collection and display of measurement data.

  • Laser Yangın Algılama Beam Dedektörler | Platin Teknoloji

    Laser Fire Detection Beam Detectors Optical Beam Smoke Detector is used to provide "wide area" smoke detection. These are generally practical. Traditional point type detector is used in environments where installation and operation is difficult. (installation, wiring and maintenance) It also provides wide coverage at low cost. Optical Beam Smoke Detectors are ideal for high ceilings, dusty and dirty environments, or you may encounter extremely hot environments. Typical applications: - Conference and Exhibition Centers - Shopping malls - Historical buildings - Mosques - Museums - High Ceiling areas - Production Facilities - Warehouses - Airports - Hotels and Casinos - Sports and Entertainment Centers Beam Smoke Detector Types: Optical Beam Smoke Detector works on the principle of darkening of light. Optical Beam Smoke Detector photosensitive element sees light produced by the Transmitter in normal condition. The receiver is calibrated to a preset sensitivity level based on the percentage of total blackening. There are two general types of Beam Optical Smoke Detector - Projected and Reflective. The type used will be dictated by the installation and environmental conditions and restrictions. Projected Beam Smoke Detectors: The transmitter (TX) and receiver (RX) area must be protected up to 100 meters separately installed at each end. The Receiver Control Unit is electrically connected to a second entity installed at ground level. Projected Optical Beam Smoke Detectors are less sensitive to leak reflection as the reflections go back to the Transmitter. As a result, the Projected Optical Smoke Detector Beam can operate within narrow gaps left in the operating environment. In addition, Projected Optical Smoke Detector Beam Emitter and Receiver units are often considered into compact and easy "aesthetic" architectural designs. Reflective Beam Smoke Detectors: Transmitter (TX) and Receiver (RX) are contained in one unit. Up to 100Metres away from the transmitted infrared ray reflected by the back reflector (prism), it is mounted across the unit. The receiver is connected to a control unit that can be either integrated with the Transceiver or mounted at ground level. Reflected Optical Beam Smoke Detectors use less wiring (power and wiring required only at the end of the Radio) and only require the Transceiver to be aligned. However the Reflected Optical Beam Smoke Detector Beam can be vulnerable to reflective items near the IR beam path. Because the reflector has a wide acceptance angle, it does not need to be correctly aligned at both ends of the projected Optical Smoke Detector Beam. About Fireray FFE Beam Detector GST 9105-E Işın Tipi Beam Dedektörü Everday EV6100 Beam Dedektör About Vesda Osid Beam Detector TNA TX7130 Tanda Beam Dedektör Hakkında

  • Yüz Tanıma Ve Eşkal Tespit Yazılımlar | Platin Teknoloji

    Face Recognition and Equivalent Detection Software Facial features are described as very important distinguishing features that individuals have innate, such as fingerprints, that make them different and unique from other people. This discrimination disappears only in identical twins. The basis of face recognition software is based on the system automatically capturing and comparing some characteristics and features of that face from the images of existing faces. The most important feature of this technology is that it is a technology that provides the desired security in the area where it is applied without causing anyone to experience stress or discomfort. The human faces in the video images to be taken with the existing systems can be automatically detected and followed with these software. Therefore, while individuals maintain their usual mobility, security research can be performed on them and no discomfort is created. Different methods or approaches are used in face identification technology, and the success of the application to be chosen determines the quality of the chosen method or approach. The solutions we have developed for our customers are shaped by our expert staff on the basis of the FaceVACS® system technology of the German Cognitec company, completely in line with your needs. FaceVACS® has been used successfully in the service of many governments and organizations in many parts of the world since 1996. System applications based on this software, such as the automatic border control system installed in Australia's Sydney International Airport in 2002, meet today's increasing security requirements effectively and inexpensively with future technologies at the service of security units. Suspect Identification and Tracking Automation: With the automatic face recognition system, suspicious persons can be detected automatically among the people who are in a certain place (building, facility, etc.). The system keeps the people who frequently use the space and who are known (for which reason they visited the facility) (for example, customer, cargo, catering company officer, etc.) on the white list, and the people who are not understood why they visited the facility and frequently encountered people on the black list. At this point, the system alerts the security officer (operator) when people on the black list walk around the facility, the building or the surrounding areas, and it is ensured that the reasons for their presence in the facility and its surroundings are clarified by the security unit. In our applications, suspicious persons can be defined on the basis of the parameter of the frequency of visits made in a certain period according to the requests from the institutions. Tracking Persons Wanted / Stadium Security: An important application area of ​​our automatic face recognition systems is the automatic face recognition application that tracks the sought persons. With this software, it instantly compares the faces of the searched persons registered in the database with the video images of the security cameras and automatically alarms the security units. For this purpose, our system is used for stadiums and so on. It queries the database by automatically detecting the human faces in the images captured by the security cameras placed at the entrance points of the buildings or at the points where they can see large areas with wide angle lenses. If the captured similarity is above the specified limit, these faces are presented to the attention of the security unit on the security camera monitor to be compared with live images. The final decision belongs to the operator. In addition, every event that occurs in our systems is recorded and archived together with time and camera location information. Features: - It offers the ability to automatically capture and follow human faces from video images. - It offers the opportunity to capture and follow more than one face at the same time in crowded areas. - It is easy to integrate with camera security systems. - Supports IQEye3® type cameras with integrated face grabber. - It has the feature of displaying on camera monitors as soon as the wanted person is found. - Allows the operator to limit the number of searches that look like the person in the image and define / adjust the percentage of similarity. With the scanner, people can register from the photograph to the system. - It can record people to the system from old video images. - Person can be registered to the system from the video image being recorded. - Person can be registered to the system from the photo data banks on the computer. Personnel Tracking Automation: FaceVACS-Entry personnel tracking automation entry-exit security personnel tracking automation system is an application that strengthens the ordinary security systems currently in use with face recognition technology and minimizes abuse. As it is known, various abuses may occur in existing systems from time to time, and security units have difficulties in controlling these abuses. At an entry-exit point where face recognition system is integrated, problems such as logging in with someone else's ID or not having an ID scan while logging in will not be experienced. An application that uses face recognition detects the identity of the person and the face, which is an integral part of it, from the database as a whole and alerts the security units in case of the passage of different people with different identities. In applications where the system is also configured to capture all faces in a certain area, even the passage of persons without a card does not create any security problems, because the system interrogates all faces entering through a certain door from the database in less than a second and alerts the security units when necessary. At the same time, all entries and exits that occur can be recorded retrospectively and perfectly documented. Features: - It is an excellent tool that provides real-time alerts in the fight against counterfeiting. - Uses proven and superior FaceVACS® technology. - It is an effective system with a processing time of less than a second. - Easy to integrate with existing access control and personnel tracking systems and software.

  • Hid omnikey 3021 | Platinum Technology

    HID ® Omnikey ® 3021 USB Card Reader High performance Omnikey smart card reader with USB interface One of the world's leading innovative smart card reader manufacturers HID Global offers a high-performance smart card reader in a small form factor for desktop and mobile use with the OMNIKEY® 3021 USB. The OMNIKEY® 3021 is an easy-to-install USB device suitable for all contact smart card transactions such as online banking or digital signature applications. ​ Main Features elegant design Small form factor suitable for the letter shop All major operating systems supported High speed data transmission

  • genesis edwards | Platin Teknoloji

    Genesis Edwards Siren Flasher Equipment Founded in 1872 by Robert Edwards and David Rousseau, the Edwards Company has a rich history of success. 1872- Edwards and Company was founded by Robert Edwards and David Rousseau to discover the new "Electric" phenomenon and to manufacture, sell and install battery-powered gas-fitting igniters. Among the company's first customers is a New York City church where the sextons previously climbed a 100-meter ladder to the light gas armatures above the rows. 1873 Rousseau withdraws from the partnership and is replaced by Adam Lungen. They invented and developed an electric doorbell and a burglar alarm. 1880 - The Edwards Company leaves the basement of the Lungen family's jewelery shop, moves into a three-story facility, and begins to manufacture wooden canals and enclosures for burglar alarms. 1881 - Robert Edwards receives his first patent for an electric bell. Other patents quickly followed: a retractable warning device (1882); an electric gas burner lighter (1883) for push button operation; and an electric door opener (1884). 1884 - Edwards displayed its products at the first electricity fair in the United States. Held in Philadelphia, was called the "Electricity Exhibition, National Electricians Conference". 1886 - Alongside burglar alarms and fixture igniters, the Edwards catalog lists electrically wound clocks, program systems, and coils for the first time. 1896 - Edwards stopped installing electrical devices and limited his activities to the design and manufacture of signaling, communication, and protection equipment. 1900 - Horizontally operated piston bell designed. The basic design is used for today's Edwards AdaptaBel. 1901- First national distributor of "household electrical appliances" appointed by Edwards Company. 1903 - The New York Stock Exchange bell was set to initiate the start and end of each day trading. 1912 - Edwards car call is introduced, reporting all-weather conditions for department stores. 1915 - Bronze Medal of Honor for electrical products awarded to Edwards at the Panama-Pacific Fair, San Francisco, CA. 1917 - Waterproof bells and submarine detection devices made for the Navy, a special telegraph apparatus developed for the Signal Corps. 1927- The Holland Tunnel is opened with Edwards emergency signaling installed on 2-mile twin tubes. Electrical devices ordered from Edwards for the White House. 1929 - Montreal Curb Exchange orders "Silent Call" alerts. Edwards & Company of Canada is formed. 1935 - Lungen buzz vibrating probe at the bottom of the world's deepest oil well 11,300 feet below the earth's surface. Edwards guard tour, sprinkler and fire alarm system installed at Rockefeller Center in New York City. 1936 - New glass-breaking fire stations are introduced to replace the hammer and chain types. 1938- Boeing Aircraft Co. Edwards signaling devices and signaling systems for double-deck flying clipper ships. 1941 - The world's largest car ferry, Midland City leaves Michigan waterways equipped with Edwards waterproof signals. Budd Co. has equipped its latest "Silver Meteor" trains with Edwards reporters. 1945- Edwards, Fifth Army-Navy E. 1948 - Edwards-made fire alarms are installed on SS President Cleveland and SS President Wilson, new cruise ships traveling around the world. The James H. McGraw Award, Manufacturer Medal of the Year, was presented to RS Edwards. 1950- New Edwards factory opens in Owen Sound, Ontario, Canada. 1951- Teardrop fire alarm station introduced: Called "a model of impeccable simplicity" by the Associated Press. 1956 - Production facilities for distributor products transferred to the new Pittsfield, Maine plant. 1961 - An audiovisual nurse call with patient privacy feature shown at the American Hospital Association Exposition, Atlantic City, NJ. 1962 - Edwards Corporation becomes a business unit of General Signal Corporation. 1964- Edwards fire alarm system was determined for 52-storey Vertical Assembly Building in Cape Kennedy, the largest structure in the world. 1965- Edwards systems installed in the Visual Arts Museum designed by LeCorbusier for the Harvard University campus. 1966 - Manitoba, the largest municipal public system in Canada designed and established by Edwards, police and fire control centers for the city of Winnipeg. 1967 - Edwards supplies 77 fire alarm systems to Expo '67, Montreal. 1971- JFK Performing Arts Center was equipped with Edwards fire alarm system. 1973 - Edwards buys Electrons, Inc., maker of Cat. 280 series heat detector. 1976 - Edwards introduces a new ionization smoke detector. 1979- Edwards introduces new Greenline Series Fire Alarm Chimes. 1981- Edwards incorporates the latest microprocessor technology into the next generation of "programmable" signals with the launch of the Adaptatone product line. 1982 - Edwards begins a planned expansion of hazardous audio and visual signals that will result in the most up-to-date and complete line in the industry. 1984 - The first Edwards piezo-electric signals are introduced, demonstrating the adoption of the latest technology in light duty signaling. 1985 - Edwards begins expanding a planned industrial flasher and pointer products that will result in the highest quality and most complete line in the industry today. 1986 - A new, state-of-the-art photoelectric smoke detector is introduced by Edwards. 1994- Edwards buys the signaling product line from Thomas Industries' Benjamin Division. These new products, previously produced in Sparta, TN, are consolidated at the Pittsfield, Maine plant. 1994- Edwards brought its highly advanced, multi-element sensor technology to the "Commercial" fire alarm market. State-of-the-art production processes have been established in the Pittsfield factory to support the production of these products. 1998 - Edwards offers a new range of stackable visual signals, LED blinking, and steady visual signals and flashes. The new Triliptical stacklite is designed according to customer input. 2005 - Edwards was acquired by General Electric. Edwards merged with Kalatel, Sentrol and EST businesses to become part of GE Security. The company was well placed to be an international leader in video, fire and access control. 2010 - GE Security was acquired by United Technologies Corporation. Edwards Signaling has become part of the Detection and Alert business under UTC Fire & Security. Today. . . With headquarters in Farmington, CT, manufacturing in Pittsfield, ME, distribution in Portland, TN, and Sales and Service locations around the world, it seems like a very long road to the basement of Lungen's jewelery store. Yet many of the different products Edwards manufactures today are direct descendants of gas armature igniters, electric bells, and program systems that went into the design and construction of structures more than a century ago. 860 Series Electronic Horn / Flasher Horn Xenon flash light source Flash speed 60 fpm at 1 meter 100 dB / 90 dB at 10 ft Nexus 105 AC Klaxon Electronic Tone Siren Flasher 5J Xenon beacon Quarter turn fittings for ease of installation 113dB at 1 meter / 103dB at 10ft (max); 105dB at 1 ... Nexus 105 DC Klaxon Electronic Tone Siren Flasher 5J Xenon or high efficiency LED Three alarm stages Quarter turn fittings for ease of installation Low inrush current Nexus 110 AC Klaxon Electronic Tone Siren Flasher 5J Xenon or high efficiency LED Low voltage AC variant Three alarm stages Quarter turn fasteners for ease of installation. Nexus 110 DC Klaxon Electronic Tone Siren Flasher 5J Xenon or high efficiency LED Three alarm stages Quarter turn fittings for ease of installation Low inrush current (LED ... Nexus 120 AC Klaxon Electronic Tone Siren Flasher 5J Xenon beacon Three alarm stages Quarter turn fasteners for ease of installation 120dB at 1 meter / 110dB at 10ft. (max.) .. Nexus 120 DC Klaxon Electronic Siren Flashlights - Xenon or LED Flasher 5J Xenon or high efficiency LED Three alarm stages Quarter turn fasteners 120dB at 1 meter / 110dB for ease of installation. Nexus 105 AC Klaxon Electronic Tone Siren Light 5J Xenon beacon Quarter turn fittings for ease of installation 113dB at 1 meter / 103dB at 10ft (max); 105dB at 1 ... Nexus 110 AC Klaxon Electronic Tone Siren Flasher 5J Xenon or high efficiency LED Low voltage AC variant Three alarm stages Quarter turn fasteners for ease of installation ... Nexus 120 DC Klaxon Electronic Siren Flashlights - Xenon or LED Flasher 5J Xenon or high efficiency LED Three alarm stages Quarter turn fasteners for ease of installation 120dB at 1 meter / 110dB ... 95 Series Horn-type 85 dB Audible / Visual Flasher AdaptaBeacon Light Duty Strobe Weatherproof Optically designed fresnel lens Built-in, base-mounted horn - 85 dB at 3.05 m (10 feet) Immunity ... 51SIN Series Horn PLC Compatible AdaptaBeacon® Fixed Outdoor Lights Weatherproof Built-in base mounted horn 85 dB at 10 feet (3,05 m) Cast base, ... 51 Series Horn PLC Compatible AdaptaBeacon Flashing Light Flasher Weatherproof Built-in base mounted horn of 85 dB at 10 feet (3.05 m) Cast base, 108 Series Multiple Status LED 3 LED visual signals in one compact housing Option to add an additional module for a fourth light using one. G1R-HDVM-E Genesis Series Electronic Sounder-Beacon, Red, EN54-23 Approved UTC Edwards G1R-VM-E Genesis Series Electronic Flasher, Red, EN54-23 Approved UTC Edwards G1R-HD-E Genesis Series Electronic Siren, Red UTC Edwards G1RB-MP Genesis Series Surface Mount Box for Sounders / Beacons, Red UTC Edwards

  • Digitex Türkiye | Platin Teknoloji

    Digitex Community Emergency and Disaster Warning System Digitex brand offers integrated disaster management, emergency sound and warning siren systems. Comprehensive solutions can be offered with sirens that communicate with IP-based and alternative sources. Primary digitex products are warning systems for mass notification with graphical interfaces for sirens control (digital map) and high power DSE Electronic Sirens. Besides standard offerings, Platan also designs and manufactures special devices. Main users of Digitex systems are: Civil Defense, Fire Services, Medical Rescue Teams, Army and other rescue services, industrial facilities and the commercial sector. On the Platin Technology side, with Digitex products sold in Turkey and the Turkish Republics, it offers sound and siren systemic warning solutions in accordance with the emergency and disaster management scenarios of all major cities, regardless of size. For detailed information, you can reach Platinum Technology Experts.

  • Kablo Tipi Yangın Algılama Sistemleri | Platin Teknoloji

    Linear Cable Type Fire Detection Systems Kablo Tipi Yangın Algılama Sistemleri: Görüntü In case of fire detection problems that cannot be solved by conventional fire detection detectors in tunnels, ventilation ducts, shafts, cable trays, power plants and industrial facilities, special cable type sensors to be installed at risky points and sudden temperature changes at the points are detected and fire is detected with Linear cable type fire detectors. Linear Heat Detection is a versatile and economical fire detection product. Designed for use in a wide range of fire and heat detection applications, Linear cable is suitable for harsh environmental conditions where maintenance access is in the physical or hazardous area and / or where there is a requirement that cost-effective fire detection is installed. It can be used close to risky hazardous areas. Linear Heat Sensing cable is a combination of advanced polymer and digital technologies that can detect heat conditions anywhere along the length of the cable. The cable consists of a single heat sensitive polymer outer layer, insulated with two to three metallic conductors designed to break at specific process temperatures. These twisted conductors contact and change in ambient temperature allow to initiate a fire alarm condition from the control panel without calibration. Neither does this unique product need to be heated to initiate a fire alarm of a certain length, adding to the versatility. For more flexibility, Linear Heat Detection can be used with fire alarm control panels using one of the addressable monitor modules on the cable, or can be connected directly to a detection circuit by connecting cable. In addition, the option finding distance heat source interacts with linear heat detection fire Provides the control panel to determine and view the exact location, feet or meters from the panel. This small easy to install and maintain fire detection suite offers an enormous amount of valuable information. Easy installation and maintenance Minimal false alarm Provides hazard coverage to the cable at all points for maximum protection Compatible with Fike intelligent and conventional detection and fire alarm panels Available in a variety of lengths, cable sheathing and alarm temperatures for maximum flexibility. Scope of application Cable channels - Pans Conveyor belts Power Distribution apparatus: switchgear, transformers, motor control centers Dust collectors / additional chambers • Cooling Towers Warehouses / shelf storage • Mines Pipelines Bridges, piers, boats Refrigerated storage Tank areas Aircraft hangars Power plants • Factories Can the Protectowire Linear Heat Detector be used on control panels of other manufacturers? Yes, the electrical specifications of the Protectowire Linear Heat Detector are compatible with most manufacturer's control panels. The system designer should verify compatibility with the panel manufacturer of the Protectowire Linear Heat Detector. Due to the limitations in Protectowire length for each zone, the resistance of the conductors must be determined. Protectowire Control Panels are specially designed and approved for use with Protectowire Linear Heat Detectors and are recommended to ensure compatibility and ensure sole source system responsibility. What is the maximum listed range for each type of Protectowire Linear Heat Detector in the open field? The listed gap detector mounting layout will be used as a guide or starting point. Reduced space required based on factors such as ceiling height and construction, physical obstacles, air movement, or the authority to have Jurisdiction (AHJ). Maximum listed span for each type of Protectowire Linear Heat Detector as below: 30 feet (9.14m) to center, Type The range is listed for the Factory Mutual 155 ° F and 190 ° F points types EPC, EPR, XCR and XLT - TRI - 15 feet (4.6 meters) to the center. 25 feet (7.6 m) in the center - Protectowire 220 ° F and 280 ° F Types EPC and XCR.Protectowire 356 ° F Types EPC and XCR only points for proximity detection and do not have a range of points.Underwriters Laboratories (except Type TRI) all Gaps, Listed on models - 50 feet (15.24 meters) from the center. The TRI is FM and UL Listed approved only. Can the Protectowire Linear Heat Detector, with different alarm temperatures, be mounted in the same area? Yes, the Protectowire Linear Heat Detector (excluding Tri-Wire) may have the same internal structure and be directly spliced ​​in the same starting device circuit. This gives a single Protectowire Linear Heat Detector zone to protect multiple areas with different ambient temperatures. How is overheating or fire location detected in a Protectowire Linear Heat Detection zone? All Protectowire FireSystem control panels can be provided with the unique Alarm point location Meter. This feature allows control panels to display the linear distance (feet / meter) to the digital overheat point. Linear Cable Type Fire Detector Types PHSC-135-XLT Cable Type Temperature Detector - 57 ° C (meters) Protectowire PHSC-135-XLT-M Cable Type Temperature Detector - 57 ° C (meter) with Steel Wire PHSC-155-XCR Cable Type Temperature Detector - 68 ° C (meters) Protectowire PHSC-155-XCR-M Cable Type Temperature Detector - 68 ° C (meter) with Steel Wire PHSC-190-XCR Cable Type Temperature Detector - 88 ° C (meters) Protectowire PHSC-190-XCR-M Cable Type Temperature Detector - 88 ° C (meter) with Steel Wire PHSC-220-XCR Cable Type Temperature Detector - 105 ° C (meters) Protectowire PHSC-220-XCR-M Cable Type Temperature Detector - 105 ° C (meter) with Steel Wire PHSC-280-XCR Cable Type Temperature Detector - 138 ° C (meters) Protectowire PHSC-280-XCR-M Cable Type Temperature Detector - 138 ° C (meter) with Steel Wire PHSC-356-XCR Cable Type Temperature Detector - 180 ° C (meters) Protectowire PHSC-356-XCR-M Cable Type Temperature Detector - 180 ° C (meter) with Steel Wire PIM-120 Protectowire Mini Zone Interface Module - 1 Class B Detection Zone PIM-430 Protectowire Zone Interface Module - 2 Detection Zones PIM-430D Protectowire Zone Interface Module - 2 Detection Zones, Alarm Quantity Display PIM-430DE Protectowire Zone Interface Module - 2 Detection Zones, Alarm Meter Display, External Type Enclosed PIM-430DE-I Protectowire Intrinsically Safe Zone Interface Module - 2 Detection Zones, Alarm Meter Display, External Type Enclosed, 2 Zener Barriers Included PIM-430E Protectowire Zone Interface Module - 2 Detection Zones, External Type Enclosed PIM-430E-I Protectowire Intrinsically Safe Zone Interface Module - 2 Detection Zones, External Type Enclosed, 2 Zener Barriers Included

  • İnsan Sayma Sistemleri | Platin Teknoloji

    People Counting Systems Has there been fewer visitors, or has there been a decrease in the number of customers with no noticeable change in the number of visitors? Here is the answer to this critical question, Financial metrics alone cannot really help retailers measure store performance. You can observe that sales have dropped compared to the previous month or Year, but are you using data that helps you comment on why it went down? Did the store have fewer visitors, or did the number of customers decrease with no noticeable change in the number of visitors? The answer to this critical question is the most important factor that enables retailers to effectively analyze their sales figures, evaluate opportunities and ultimately increase their sales figures. By measuring the human traffic entering and leaving your store with the people counting software via Platin Technology Camera, - Analyze your store performances !! - How useful is advertising work? - How accurate are the store opening hours? - Is staff distribution optimized? - What is the Conversion Rate of the store? Allows you to find answers to your questions !! Unfortunately, the most basic metric of the retail industry is either not used at all or used incorrectly. If the managers do not monitor and analyze the store traffic, how do they manage their stores? Hundreds of people visit a store every day. While some of these visitors successfully become customers, hundreds of them leave the store without shopping. The ratio of the number of visitors converting to customers to the total number of visitors gives the conversion rate for a store. This ratio is the most basic metric of the retail industry. CONVERSION RATE = NUMBER OF CUSTOMERS THE NUMBER OF VISITORS INTERFERENCE - IMPACT FACTOR You can observe the effects of store and window designs, visual marketing and innovations, promotions, campaigns and discounts on the number of visitors. ADVERTISING EXPENSES OPTIMIZATION: While advertising and store organization are used to attract and influence customers, measuring human traffic is also used to measure how these organizations are delivering. Normally it is a success for a company to increase its sales by 7%, but there is one more point to be analyzed. If the traffic of this store has increased by 30%, it is observed that the sales potential of the store is fully utilized. By measuring human traffic, you find a relationship based on concrete data between sales and number of visitors, and accordingly, you optimize your advertising and promotion expenses. PERFORMANCE COMPARISON: A detailed analysis of human traffic allows you to compare store and non-store variables in different locations. It allows you to get comprehensive information about your staff at each store. In this way, you can easily compare the store performances with each other and make more fair and conscious evaluations about the personnel. For example, if there is a decrease in the sales figures of a store and the conversion rate is stable, it means that the reason for the decrease in sales figures is out of store factors rather than personnel performance.

  • Calectro Türkiye | Platin Teknoloji

    Calectro Flood and Moisture Detection Systems Calectro was founded in Gothenburg in 1969 by a young technician, Karl Johan Pettersen. The company was established as an agency company for suppliers in Switzerland and Denmark. Including program electronic thermostats, level controls, time relays etc. The main idea was to find customers with special needs and develop them in close cooperation with the customer. This quickly led to the development of the first electronic overfill protection approved for oil tanks. A completely new electronic freezer protection has also been developed through close contact with a number of control and regulatory companies. In the 1970s and 1980s the company expanded significantly, and in the late 1980s it was expanded to include its own development and production, including Calectro's offering. One-pipe smoke detector for the UG-1 ventilation system, which has become an instant success. Since then, Calectro has offered to develop quality products from accredited suppliers, as well as products developed specifically for its customers. 50 years after its inception, Calectro is a full-fledged technology and distribution company with dealers in many countries and a strong Swedish customer base. Perhaps the best known product is the Uniguard® single-pipe smoke detector, currently used by many project firms in the control and regulation industry in Turkey, Sweden and Europe. Water and Moisture Leak Detection Systems in Platinum Technology; Thanks to this system applied to system rooms, cash registers, storage areas and places affected by water and moisture, the system will activate the siren unit in case of moisture or water formation that may be a risk. According to the pre-prepared scenario, the water discharge engine will activate the heating system and the ventilation system. and if it occurs outside of working hours, it will transmit information by calling the users' phones. Flood detection and alarm system can send mail and sms according to the requests. You can also keep all information in the event memory and report it. With the smart phone application, you can manage the system, report it and receive instant notifications. You can reach Turkey-wide Calectro flood and moisture detection products and special prices for your projects from Platinum Technology. Digital Type Detection Systems - Equipment used - Water detection sensor - Humidity detection sensor - Control Panel - Siren - Telephone search device - Web connection module - SMS module Water Humidity and Leak Detection System Application Areas IT / Server system Rooms Electrical Rooms Heating Cooling centers Data Centers · Hotels Kitchen / Toilet & Vending Areas Hospitals Empty Complexes Supermarkets · Museums Art Galleries Archive Facilities

bottom of page